SAM3U2E Atmel Corporation, SAM3U2E Datasheet - Page 722

no-image

SAM3U2E

Manufacturer Part Number
SAM3U2E
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3U2E

Flash (kbytes)
128 Kbytes
Pin Count
144
Max. Operating Frequency
96 MHz
Cpu
Cortex-M3
# Of Touch Channels
57
Hardware Qtouch Acquisition
No
Max I/o Pins
96
Ext Interrupts
96
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Hi-Speed
Usb Interface
Device
Spi
5
Twi (i2c)
2
Uart
5
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
12
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
36
Self Program Memory
YES
External Bus Interface
1
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
35.7.5.3
Figure 35-35. IrDA Demodulator Operations
722
722
Receiver
Counter
Value
Input
MCK
RXD
SAM3U Series
SAM3U Series
IrDA Demodulator
6
Rejected
5
Pulse
4
Table 35-12. IrDA Baud Rate Error (Continued)
The demodulator is based on the IrDA Receive filter comprised of an 8-bit down counter which is
loaded with the value programmed in US_IF. When a falling edge is detected on the RXD pin,
the Filter Counter starts counting down at the Master Clock (MCK) speed. If a rising edge is
detected on the RXD pin, the counter stops and is reloaded with US_IF. If no rising edge is
detected when the counter reaches 0, the input of the receiver is driven low during one bit time.
Figure 35-35
As the IrDA mode uses the same logic as the ISO7816, note that the FI_DI_RATIO field in
US_FIDI must be set to a value higher than 0 in order to assure IrDA communications operate
correctly.
Peripheral Clock
40 000 000
3 686 400
20 000 000
32 768 000
40 000 000
3 686 400
20 000 000
32 768 000
40 000 000
3 686 400
20 000 000
32 768 000
40 000 000
3 686 400
20 000 000
32 768 000
3
2
6
illustrates the operations of the IrDA demodulator.
6
5
Baud Rate
4
Accepted
57 600
38 400
38 400
38 400
38 400
19 200
19 200
19 200
19 200
Pulse
9 600
9 600
9 600
9 600
2 400
2 400
2 400
3
2
1
0
107
130
130
213
260
521
853
CD
43
33
53
65
12
65
24
96
6
Baud Rate Error
0.93%
0.00%
1.38%
0.63%
0.16%
0.00%
0.16%
0.31%
0.16%
0.00%
0.16%
0.16%
0.16%
0.00%
0.03%
0.04%
6430E–ATARM–29-Aug-11
6430E–ATARM–29-Aug-11
Pulse Time
19.53
19.53
19.53
19.53
78.13
78.13
78.13
3.26
4.88
4.88
4.88
4.88
9.77
9.77
9.77
9.77

Related parts for SAM3U2E