SAM3U2E

Manufacturer Part Number
SAM3U2E
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3U2E

Flash (kbytes)
128 Kbytes
Pin Count
144
Max. Operating Frequency
96 MHz
Cpu
Cortex-M3
# Of Touch Channels
57
Hardware Qtouch Acquisition
No
Max I/o Pins
96
Ext Interrupts
96
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Hi-Speed
Usb Interface
Device
Spi
5
Twi (i2c)
2
Uart
5
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
12
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
36
Self Program Memory
YES
External Bus Interface
1
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
Figure 42-3. GOVRE and OVREx Flag Behavior
6430E–ATARM–29-Aug-11
(ADC_CHSR)
(ADC_CHSR)
ADC_LCDR
ADC_CDR0
ADC_CDR1
(ADC_SR)
(ADC_SR)
(ADC_SR)
(ADC_SR)
(ADC_SR)
GOVRE
ADTRG
DRDY
OVRE0
EOC0
EOC1
CH0
CH1
Undefined Data
Undefined Data
If the ADC_CDR is not read before further incoming data is converted, the corresponding Over-
run Error (OVRE) flag is set in the Status Register (ADC_SR).
In the same way, new data converted when DRDY is high sets the bit GOVRE (General Overrun
Error) in ADC_SR.
The OVRE and GOVRE flags are automatically cleared when ADC_SR is read.
Warning: If the corresponding channel is disabled during a conversion or if it is disabled and
then reenabled during a conversion, its associated data and its corresponding EOC and OVRE
flags in ADC_SR are unpredictable.
Conversion
Undefined Data
Conversion
Data A
Data A
Data B
Conversion
Data B