Specifications of Z16FMC32AG20EG

Processor Series
Z16FMC
Core
ZNEO
Data Bus Width
16 bit
Program Memory Type
Flash
Program Memory Size
32 KB
Data Ram Size
2 KB
Interface Type
I2C, SPI, UART
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
46
Operating Supply Voltage
2.7 V to 3.6 V
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Package / Case
LQFP-64
Development Tools By Supplier
Z16FMC28200KITG
Minimum Operating Temperature
- 40 C
Core Processor
ZNEO
Core Size
16-Bit
Speed
20MHz
Connectivity
I²C, IrDA, LIN, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
46
Eeprom Size
-
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z16FMC32AG20EG
Manufacturer:
Zilog
Quantity:
160
Part Number:
Z16FMC32AG20EG
Manufacturer:
Zilog
Quantity:
10 000
PS028702-1210
CONTINUOUS Mode
In CONTINUOUS mode, the timer counts up to the 16-bit Reload value stored in the
timer reload high and low byte registers. After reaching the Reload value, the timer gener-
ates an interrupt, the count value in the timer high and low byte registers is reset to
and counting resumes. If the timer output alternate function is enabled, the timer output
pin changes state (from Low to High or High to Low) after timer Reload.
Observe the following steps to configure a timer for CONTINUOUS mode and initiate
count:
1. Write to the timer control registers to:
2. Write to the timer high and low byte registers to set the starting count value (usually
3. Write to the timer reload high and low byte registers to set the Reload period.
4. Enable the timer interrupt, if required and set the timer interrupt priority by writing to
5. When using the timer output function, configure the associated GPIO port pin for the
6. Write to the Timer Control 1 Register to enable the timer and initiate counting.
The timer period is calculated by the following equation:
If an initial starting value other than
isters, use the ONE-SHOT mode equation to determine the first timeout period.
COUNTER and COMPARATOR COUNTER Modes
In COUNTER mode, the timer counts input transitions from a GPIO port pin. The timer
input is taken from the associated GPIO port pin. The TPOL bit in the Timer Control 1
Register selects whether the count occurs on the rising edge or the falling edge of the timer
input signal. In COUNTER mode, the prescaler is disabled.
Continuous Mode Time-Out Period(s) =
0001H). This only affects the first pass in CONTINUOUS mode. After the first timer
reload in CONTINUOUS mode, counting always begins at the reset value of
the relevant interrupt registers.
timer output alternate function.
Disable the timer
Configure the timer for CONTINUOUS mode
Set the prescale value
Set the initial output level (High or Low) through TPOL for the timer output alter-
nate function
P R E L I M I N A R Y
0001H
is loaded into the timer high and low byte reg-
System Clock Frequency (Hz)
Z16FMC Series Motor Control MCUs
Reload Value x Prescale