M29W256GH7AN6E NUMONYX, M29W256GH7AN6E Datasheet - Page 37

no-image

M29W256GH7AN6E

Manufacturer Part Number
M29W256GH7AN6E
Description
Flash Mem Parallel 3V/3.3V 256M-Bit 32M x 8/16M x 16 70ns 56-Pin TSOP Tray
Manufacturer
NUMONYX
Datasheet

Specifications of M29W256GH7AN6E

Package
56TSOP
Cell Type
NOR
Density
256 Mb
Architecture
Sectored
Block Organization
Symmetrical
Location Of Boot Block
Bottom|Top
Typical Operating Supply Voltage
3|3.3 V
Sector Size
128KByte x 256
Timing Type
Asynchronous
Operating Temperature
-40 to 85 °C
Interface Type
Parallel

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W256GH7AN6E
Manufacturer:
MICRON
Quantity:
1 400
Part Number:
M29W256GH7AN6E
Manufacturer:
ST
0
Part Number:
M29W256GH7AN6E
Manufacturer:
MICRON/镁光
Quantity:
20 000
6.3
6.3.1
Table 15.
1. X don't care, PA program address, PD program data, BAd any address in the block, WBL write buffer
Fast program commands
The M29W256GH/L offers a set of fast program commands to improve the programming
throughput:
See either
for a summary of the fast program commands.
After programming has started, bus read operations in the memory output the status register
content. Write to Buffer Program command can be suspended and then resumed by issuing
a Program Suspend command and a Program Resume command, respectively (see
Section 6.1.9: Program Suspend command
command).
Write to Buffer Program command set
The Write to Buffer Program command set makes use of the device's 32-word/64-byte write
buffer to speed up programming. 32 words/64 bytes can be loaded into the write buffer.
Each write buffer has the same A23-A5 addresses. The Write to Buffer Program command
dramatically reduces system programming time compared to the standard non-buffered
Program command. When issuing a Write to Buffer Program command, the VPP/WP pin
can be either held High, VIH, or raised to VPPH.
See
cases.
Unlock Bypass
Unlock Bypass Program
Unlock Bypass Block Erase
Unlock Bypass Chip Erase
Unlock Bypass Reset
location. All values in the table are in hexadecimal.
Table
Write to Buffer Program
Enhanced Buffered Program (valid in x 16 mode only)
Command
16,
Table
Unlock Bypass commands, 16-bit mode
Table 17
16,
Table 17
or
Table 18
or
Table 18
2+
2
3
2
2
for details on typical write to buffer program times in both
Add
555
X
X
X
X
depending on the configuration that is being used,
and
1st
Data
Section 6.1.10: Program Resume
AA
A0
80
80
90
Bus write operations
Add
2AA
BAd
PA
X
X
2nd
Data
PD
55
30
10
0
(1)
Add
555
3rd
Data
20
37/97