HD6417011VX20V Renesas Electronics America, HD6417011VX20V Datasheet - Page 210

MPU 5V 0K 100-QFP

HD6417011VX20V

Manufacturer Part Number
HD6417011VX20V
Description
MPU 5V 0K 100-QFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7010r
Datasheet

Specifications of HD6417011VX20V

Core Processor
SH-2
Core Size
32-Bit
Speed
20MHz
Connectivity
EBI/EMI, SCI
Peripherals
POR, PWM
Number Of I /o
11
Program Memory Type
ROMless
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 7x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417011VX20V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Bit 6: RDRF
0
1
Note: The RDR and RDRF are not affected by detection of receive errors or by clearing of the RE
Bit 5: ORER
0
1
200
Bit 6—Receive Data Register Full (RDRF): Indicates that RDR contains received data.
Bit 5—Overrun Error (ORER): Indicates that data reception ended abnormally due to an
overrun error.
bit to 0 in the serial control register. They retain their previous contents. If RDRF is still set
to 1 when reception of the next data ends, an overrun error (ORER) occurs and the
received data is lost.
Description
RDR does not contain valid received data (initial value)
RDRF is cleared to 0 when the chip is power-on reset, software reads RDRF
after it has been set to 1, then writes 0 in RDRF
RDR contains valid received data
RDRF is set to 1 when serial data is received normally and transferred from RSR
to RDR
Description
Receiving is in progress or has ended normally (initial value). Clearing the RE bit
to 0 in the serial control register does not affect the ORER bit, which retains its
previous value.
ORER is cleared to 0 when the chip is power-on reset or software reads ORER
after it has been set to 1, then writes 0 in ORER
A receive overrun error occurred. RDR continues to hold the data received
before the overrun error, so subsequent receive data is lost. Serial receiving
cannot continue while ORER is set to 1.
ORER is set to 1 if reception of the next serial data ends when RDRF is set to 1

Related parts for HD6417011VX20V