DF2506BR26DV Renesas Electronics America, DF2506BR26DV Datasheet - Page 530

IC H8S/2506 MCU FLASH 176-LFBGA

DF2506BR26DV

Manufacturer Part Number
DF2506BR26DV
Description
IC H8S/2506 MCU FLASH 176-LFBGA
Manufacturer
Renesas Electronics America
Series
H8® H8S/2500r
Datasheets

Specifications of DF2506BR26DV

Core Processor
H8S/2000
Core Size
16-Bit
Speed
26MHz
Connectivity
I²C, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
104
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
176-LFBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2506BR26DV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 14 I
14.3.2
ICCR1 issues start/stop conditions, manipulates the SDA pin, monitors the SCL pin, and controls
reset in the control part of the I
Rev. 6.00 Sep. 24, 2009 Page 482 of 928
REJ09B0099-0600
Bit
7
6
5
Bit Name
BBSY
SCP
SDAO
I
2
C Bus Control Register 2 (ICCR2)
2
C Bus Interface 2 (IIC2)
Initial
Value
0
1
1
R/W
R/W
R/W
R/W
2
C bus interface 2.
Description
Bus Busy
This bit enables to confirm whether the I
or released and to issue start/stop conditions in master
mode. With the clocked synchronous serial format, this bit
has no meaning. With the I
when the SDA level changes from high to low under the
condition of SCL = high, assuming that the start condition
has been issued. This bit is cleared to 0 when the SDA
level changes from low to high under the condition of SCL
= high, assuming that the stop condition has been issued.
Write 1 to BBSY and 0 to SCP to issue a start condition.
Follow this procedure when also re-transmitting a start
condition. Write 0 in BBSY and 0 in SCP to issue a stop
condition. To issue start/stop conditions, use the MOV
instruction.
Start/Stop Issue Condition Disable
The SCP bit controls the issue of start/stop conditions in
master mode.
To issue a start condition, write 1 in BBSY and 0 in SCP. A
retransmit start condition is issued in the same way. To
issue a stop condition, write 0 in BBSY and 0 in SCP. This
bit is always read as 1. If 1 is written, the data is not stored.
SDA Output Value Control
This bit is used with SDAOP when modifying output level of
SDA. This bit should not be manipulated during transfer.
0: When reading, SDA pin outputs low.
1: When reading, SDA pin outputs high.
When writing, SDA pin is changed to output low.
When writing, SDA pin is changed to output Hi-Z
(outputs high by external pull-up resistance).
2
C bus format, this bit is set to 1
2
C bus is occupied

Related parts for DF2506BR26DV