DF2506BR26DV Renesas Electronics America, DF2506BR26DV Datasheet - Page 498

IC H8S/2506 MCU FLASH 176-LFBGA

DF2506BR26DV

Manufacturer Part Number
DF2506BR26DV
Description
IC H8S/2506 MCU FLASH 176-LFBGA
Manufacturer
Renesas Electronics America
Series
H8® H8S/2500r
Datasheets

Specifications of DF2506BR26DV

Core Processor
H8S/2000
Core Size
16-Bit
Speed
26MHz
Connectivity
I²C, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
104
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
176-LFBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2506BR26DV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 13 Serial Communication Interface (SCI)
Rev. 6.00 Sep. 24, 2009 Page 450 of 928
REJ09B0099-0600
[3]
No
No
Read receive data in RDR, and
clear RDRF flag in SSR to 0
Clear ORER flag in SSR to 0
Read ORER flag in SSR
Read RDRF flag in SSR
Clear RE bit in SCR to 0
Overrun error processing
All data received?
Error processing
Start reception
Initialization
ORER = 1
RDRF = 1
<End>
<End>
Figure 13.19 Sample Serial Reception Flowchart
Yes
Yes
No
(Continued below)
Error processing
Yes
[2]
[1]
[3]
[4]
[5]
[1] SCI initialization:
[2] [3] Receive error processing:
[4] SCI status check and receive data
[5] Serial reception continuation
Note: * The case, where the RDRF flag check and
The RxD pin is automatically
designated as the receive data input
pin.
If a receive error occurs, read the
ORER flag in SSR, and after
performing the appropriate error
processing, clear the ORER flag to 0.
Transfer cannot be resumed if the
ORER flag is set to 1.
read:
Read SSR and check that the RDRF
flag is set to 1, then read the receive
data in RDR and clear the RDRF flag
to 0.
Transition of the RDRF flag from 0 to 1
can also be identified by an RXI
interrupt.
procedure:
To continue serial reception, before
the final bit of the current frame is
received, reading the RDRF flag,
reading RDR, and clearing the RDRF
flag to 0 should be finished. The
RDRF flag is cleared automatically
when the DTC* is activated by a
receive data full interrupt (RXI) request
and the RDR value is read.
occurs only when the DISEL bit in DTC is 0
with the transfer counter other than 0.
Therefore, when the DISEL bit is 1, or
both the DISEL bit and the transfer counter are 0,
give the CPU an instruction to clear the RDRF flag.
clearing are automatically executed by DTC,

Related parts for DF2506BR26DV