Specifications of HD64F36077GHV

No. Of I/o's
47
Ram Memory Size
4KB
Cpu Speed
20MHz
No. Of Timers
4
Digital Ic Case Style
LQFP
Supply Voltage Range
4.5V
Core Size
16bit
Program Memory Size
56KB
Oscillator Type
External Only
Controller Family/series
H8/300H
Peripherals
ADC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F36077GHV
Manufacturer:
RENESAS
Quantity:
340
Part Number:
HD64F36077GHV
Manufacturer:
Renesas
Quantity:
200
Part Number:
HD64F36077GHV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
16.4.4
Figure 16.7 shows an example of operation for reception in asynchronous mode. In serial
reception, the SCI3 operates as described below.
1. The SCI3 monitors the communication line. If a start bit is detected, the SCI3 performs
2. If an overrun error occurs (when reception of the next data is completed while the RDRF flag
3. If a parity error is detected, the PER bit in SSR is set to 1 and receive data is transferred to
4. If a framing error is detected (when the stop bit is 0), the FER bit in SSR is set to 1 and receive
5. If reception is completed successfully, the RDRF bit in SSR is set to 1, and receive data is
Serial
data
RDRF
FER
LSI
operation
User
processing
internal synchronization, receives receive data in RSR, and checks the parity bit and stop bit.
is still set to 1), the OER bit in SSR is set to 1. If the RIE bit in SCR3 is set to 1 at this time, an
ERI interrupt request is generated. Receive data is not transferred to RDR.
RDR. If the RIE bit in SCR3 is set to 1 at this time, an ERI interrupt request is generated.
data is transferred to RDR. If the RIE bit in SCR3 is set to 1 at this time, an ERI interrupt
request is generated.
transferred to RDR. If the RIE bit in SCR3 is set to 1 at this time, an RXI interrupt request is
generated. Continuous reception is possible because the RXI interrupt routine reads the receive
data transferred to RDR before reception of the next receive data has been completed.
Serial Data Reception
1
Start
bit
Figure 16.7 Example of SCI3 Reception in Asynchronous Mode
0
D0
D1
Receive
1 frame
data
(8-Bit Data, Parity, One Stop Bit)
D7
Parity
0/1
bit
RXI request
Stop
bit
1
Start
bit
0
D0
RDRF
cleared to 0
RDR data read
Section 16 Serial Communication Interface 3 (SCI3)
1 frame
D1
Receive
data
Rev. 1.00 Sep. 16, 2005 Page 299 of 490
D7
Parity
0/1
bit
Stop
bit
0
0 stop bit
detected
Mark state
(idle state)
1
REJ09B0216-0100
ERI request in
response to
framing error
Framing error
processing