C8051F962-A-GM Silicon Labs, C8051F962-A-GM Datasheet - Page 389

no-image

C8051F962-A-GM

Manufacturer Part Number
C8051F962-A-GM
Description
8-bit Microcontrollers - MCU 128KB, DC-DC, AES DQFN76
Manufacturer
Silicon Labs
Datasheet

Specifications of C8051F962-A-GM

Rohs
yes
Core
8051
Processor Series
C8051
Data Bus Width
8 bit
Maximum Clock Frequency
25 MHz
Program Memory Size
128 KB
Data Ram Size
8448 B
On-chip Adc
Yes
Operating Supply Voltage
2.5 V to 3.3 V
Operating Temperature Range
- 40 C to + 85 C
Package / Case
DQFN-76
Mounting Style
SMD/SMT
Number Of Programmable I/os
57
Number Of Timers
4
SFR Definition 28.2. SMB0CN: SMBus Control
SFR Page = All Pages; SFR Address = 0xC0; Bit-Addressable
Name
Reset
Bit
Type
7
6
5
4
3
2
1
0
Bit
ARBLOST SMBus Arbitration Lost
TXMODE SMBus Transmit Mode
MASTER SMBus Master/Slave
ACKRQ
Name
MASTER
STO
ACK
STA
SI
R
7
0
Indicator. This read-only bit
indicates when the SMBus is
operating as a master.
Indicator. This read-only bit
indicates when the SMBus is
operating as a transmitter.
SMBus Start Flag.
SMBus Stop Flag.
SMBus Acknowledge
Request.
Indicator.
SMBus Acknowledge.
SMBus Interrupt Flag.
This bit is set by hardware
under the conditions listed in
Table 15.3. SI must be cleared
by software. While SI is set,
SCL is held low and the
SMBus is stalled.
TXMODE
R
6
0
Description
R/W
STA
5
0
STO
R/W
Rev. 0.5
0: SMBus operating in
slave mode.
1: SMBus operating in
master mode.
0: SMBus in Receiver
Mode.
1: SMBus in Transmitter
Mode.
0: No Start or repeated
Start detected.
1: Start or repeated Start
detected.
0: No Stop condition
detected.
1: Stop condition detected
(if in Slave Mode) or pend-
ing (if in Master Mode).
0: No Ack requested
1: ACK requested
0: No arbitration error.
1: Arbitration Lost
0: NACK received.
1: ACK received.
0: No interrupt pending
1: Interrupt Pending
4
0
ACKRQ
Read
R
3
0
ARBLOST
R
2
0
N/A
N/A
0: No Start generated.
1: When Configured as a
Master, initiates a START
or repeated START.
0: No STOP condition is
transmitted.
1: When configured as a
Master, causes a STOP
condition to be transmit-
ted after the next ACK
cycle.
Cleared by Hardware.
N/A
N/A
0: Send NACK
1: Send ACK
0: Clear interrupt, and initi-
ate next state machine
event.
1: Force interrupt.
C8051F96x
ACK
R/W
1
0
Write
R/W
SI
0
0
389