C8051F962-A-GM Silicon Labs, C8051F962-A-GM Datasheet - Page 304

no-image

C8051F962-A-GM

Manufacturer Part Number
C8051F962-A-GM
Description
8-bit Microcontrollers - MCU 128KB, DC-DC, AES DQFN76
Manufacturer
Silicon Labs
Datasheet

Specifications of C8051F962-A-GM

Rohs
yes
Core
8051
Processor Series
C8051
Data Bus Width
8 bit
Maximum Clock Frequency
25 MHz
Program Memory Size
128 KB
Data Ram Size
8448 B
On-chip Adc
Yes
Operating Supply Voltage
2.5 V to 3.3 V
Operating Temperature Range
- 40 C to + 85 C
Package / Case
DQFN-76
Mounting Style
SMD/SMT
Number Of Programmable I/os
57
Number Of Timers
4
C8051F96x
24.2.6. Missing SmaRTClock Detector
The missing SmaRTClock detector is a one-shot circuit enabled by setting MCLKEN (RTC0CN.6) to 1.
When the SmaRTClock Missing Clock Detector is enabled, OSCFAIL (RTC0CN.5) is set by hardware if
SmaRTClock oscillator remains high or low for more than 100 µs.
A SmaRTClock Missing Clock detector timeout can trigger an interrupt, wake the device from a low power
mode, or reset the device. See Section “17. Interrupt Handler” on page 232, Section “19. Power Manage-
ment” on page 257, and Section “22. Reset Sources” on page 278 for more information.
Note: The SmaRTClock Missing Clock Detector should be disabled when making changes to the oscillator settings in
24.2.7. SmaRTClock Oscillator Crystal Valid Detector
The SmaRTClock oscillator crystal valid detector is an oscillation amplitude detector circuit used during
crystal startup to determine when oscillation has started and is nearly stable. The output of this detector
can be read from the CLKVLD bit (RTX0XCN.4).
Notes:
24.3. SmaRTClock Timer and Alarm Function
The SmaRTClock timer is a 32-bit counter that, when running (RTC0TR = 1), is incremented every
SmaRTClock oscillator cycle. The timer has an alarm function that can be set to generate an interrupt,
wake the device from a low power mode, or reset the device at a specific time. See Section “17. Interrupt
Handler” on page 232, Section “19. Power Management” on page 257, and Section “22. Reset Sources”
on page 278 for more information.
The SmaRTClock timer includes an Auto Reset feature, which automatically resets the timer to zero one
SmaRTClock cycle after the alarm 0 signal is deasserted. When using Auto Reset, the Alarm match value
should always be set to 2 counts less than the desired match value. When using the LFO in combination
with Auto Reset, the right-justified Alarm match value should be set to 4 counts less than the desired
match value. Auto Reset can be enabled by writing a 1 to ALRM (RTC0CN.2).
24.3.1. Setting and Reading the SmaRTClock Timer Value
The 32-bit SmaRTClock timer can be set or read using the six CAPTUREn internal registers. Note that the
timer does not need to be stopped before reading or setting its value. The following steps can be used to
set the timer value:
The following steps can be used to read the current timer value:
Notes:
304
1. The CLKVLD bit has a blanking interval of 2 ms. During the first 2 ms after turning on the crystal oscillator, the
2. This SmaRTClock crystal valid detector (CLKVLD) is not intended for detecting an oscillator failure. The
3. The CLKVLD bit output is driven low when BIASX2 is disabled.
1. Write the desired 32-bit set value to the CAPTUREn registers.
2. Write 1 to RTC0SET. This will transfer the contents of the CAPTUREn registers to the SmaRTClock
3. Operation is complete when RTC0SET is cleared to 0 by hardware.
1. Write 1 to RTC0CAP. This will transfer the contents of the timer to the CAPTUREn registers.
2. Poll RTC0CAP until it is cleared to 0 by hardware.
3. A snapshot of the timer value can be read from the CAPTUREn registers
1. If the system clock is faster than 4x the SmaRTClock, then the HSMODE bit should be set to allow the set and
2. If the system clock is slower than 4x the SmaRTClock, then HSMODE should be set to zero, and RTC must be
timer.
RTC0XCN.
output of CLKVLD is not valid.
missing SmaRTClock detector (CLKFAIL) should be used for this purpose.
capture operations to be concluded quickly (system clock used for transfers).