15
14
13
12
11
10
14.5.4 PTP Trigger Status Register (PTP_TSTS), Page 4
This register provides status of the PTP 1588 Triggers. The bits in this register indicate the current status of each of the Trigger
modules. The error bits will be set if the associated notification enable (TRIGN_NOTIFY) is set in the PTP Trigger Configuration
Registers.
9
8
7
6
5
4
3
2
1
0
TRIG7_ERROR
TRIG7_ACTIVE
TRIG6_ERROR
TRIG6_ACTIVE
TRIG5_ERROR
TRIG5_ACTIVE
TRIG4_ERROR
TRIG4_ACTIVE
TRIG3_ERROR
TRIG3_ACTIVE
TRIG2_ERROR
TRIG2_ACTIVE
TRIG1_ERROR
TRIG1_ACTIVE
TRIG0_ERROR
TRIG0_ACTIVE
Bit Name
TABLE 53. PTP Trigger Status Register (PTP_TSTS), address 0x17
0, RO/SC
0, RO/SC
0, RO/SC
0, RO/SC
0, RO/SC
0, RO/SC
0, RO/SC
0, RO/SC
0, RO/SC
0, RO/SC
0, RO/SC
0, RO/SC
0, RO/SC
0, RO/SC
0, RO/SC
0, RO/SC
Default
Trigger 7 Error:
This bit indicates the Trigger was improperly programmed to trigger at a time prior
to the current time. This bit will be cleared when the Trigger is disabled and/ or
re-armed.
Trigger 7 Active:
This bit indicates the Trigger is enabled and has not completed.
Trigger 6 Error:
This bit indicates the Trigger was improperly programmed to trigger at a time prior
to the current time. This bit will be cleared when the Trigger is disabled and/ or
re-armed.
Trigger 6 Active:
This bit indicates the Trigger is enabled and has not completed.
Trigger 5 Error:
This bit indicates the Trigger was improperly programmed to trigger at a time prior
to the current time. This bit will be cleared when the Trigger is disabled and/ or
re-armed.
Trigger 5 Active:
This bit indicates the Trigger is enabled and has not completed.
Trigger 4 Error:
This bit indicates the Trigger was improperly programmed to trigger at a time prior
to the current time. This bit will be cleared when the Trigger is disabled and/ or
re-armed.
Trigger 4 Active:
This bit indicates the Trigger is enabled and has not completed.
Trigger 3 Error:
This bit indicates the Trigger was improperly programmed to trigger at a time prior
to the current time. This bit will be cleared when the Trigger is disabled and/ or
re-armed.
Trigger 3 Active:
This bit indicates the Trigger is enabled and has not completed.
Trigger 2 Error:
This bit indicates the Trigger was improperly programmed to trigger at a time prior
to the current time. This bit will be cleared when the Trigger is disabled and/ or
re-armed.
Trigger 2 Active:
This bit indicates the Trigger is enabled and has not completed.
Trigger 1 Error:
This bit indicates the Trigger was improperly programmed to trigger at a time prior
to the current time. This bit will be cleared when the Trigger is disabled and/ or
re-armed.
Trigger 1 Active:
This bit indicates the Trigger is enabled and has not completed.
Trigger 0 Error:
This bit indicates the Trigger was improperly programmed to trigger at a time prior
to the current time. This bit will be cleared when the Trigger is disabled and/ or
re-armed.
Trigger 0 Active:
This bit indicates the Trigger is enabled and has not completed.