ATtiny85 Atmel Corporation, ATtiny85 Datasheet - Page 45

no-image

ATtiny85

Manufacturer Part Number
ATtiny85
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATtiny85

Flash (kbytes)
8 Kbytes
Pin Count
8
Max. Operating Frequency
20 MHz
Cpu
8-bit AVR
# Of Touch Channels
3
Hardware Qtouch Acquisition
No
Max I/o Pins
6
Ext Interrupts
6
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
4
Adc Resolution (bits)
10
Adc Speed (ksps)
15
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
0.5
Eeprom (bytes)
512
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8 to 5.5
Operating Voltage (vcc)
1.8 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
2
Output Compare Channels
5
Pwm Channels
6
32khz Rtc
No
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATtiny85-15SZ
Manufacturer:
ATMEL
Quantity:
30
Part Number:
ATtiny85-20PU
Manufacturer:
CUI
Quantity:
1 000
Part Number:
ATtiny85-20SU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATtiny85V-10SH
Manufacturer:
Intel
Quantity:
62
Part Number:
ATtiny85V-10SU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
8.4.1
8.4.1.1
8.4.1.2
2586N–AVR–04/11
Timed Sequences for Changing the Configuration of the Watchdog Timer
Safety Level 1
Safety Level 2
“Timed Sequences for Changing the Configuration of the Watchdog Timer” on page 45
details.
Table 8-1.
Figure 8-7.
The sequence for changing configuration differs slightly between the two safety levels. Separate
procedures are described for each level.
In this mode, the Watchdog Timer is initially disabled, but can be enabled by writing the WDE bit
to one without any restriction. A timed sequence is needed when disabling an enabled Watch-
dog Timer. To disable an enabled Watchdog Timer, the following procedure must be followed:
In this mode, the Watchdog Timer is always enabled, and the WDE bit will always read as one. A
timed sequence is needed when changing the Watchdog Time-out period. To change the
Watchdog Time-out, the following procedure must be followed:
WDTON
Unprogrammed
Programmed
1. In the same operation, write a logic one to WDCE and WDE. A logic one must be writ-
2. Within the next four clock cycles, in the same operation, write the WDE and WDP bits
1. In the same operation, write a logical one to WDCE and WDE. Even though the WDE
2. Within the next four clock cycles, in the same operation, write the WDP bits as desired,
ten to WDE regardless of the previous value of the WDE bit.
as desired, but with the WDCE bit cleared.
always is set, the WDE must be written to one to start the timed sequence.
but with the WDCE bit cleared. The value written to the WDE bit is irrelevant.
WDT Configuration as a Function of the Fuse Settings of WDTON
Watchdog Timer
Safety
Level
1
2
WATCHDOG
OSCILLATOR
RESET
128 kHz
WDP0
WDP1
WDP2
WDP3
WDE
WDT Initial
State
Disabled
Enabled
How to Disable the
WDT
Timed sequence
Always enabled
MCU RESET
PRESCALER
WATCHDOG
ATtiny25/45/85
How to Change Time-
out
No limitations
Timed sequence
for
45

Related parts for ATtiny85