PEB20256E-V21 Infineon Technologies, PEB20256E-V21 Datasheet - Page 162

IC CONTROLLER INTERFACE 388-BGA

PEB20256E-V21

Manufacturer Part Number
PEB20256E-V21
Description
IC CONTROLLER INTERFACE 388-BGA
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB20256E-V21

Function
Multichannel Network Interface Controller (MUNICH)
Interface
HDLC, PPP, Serial, TMA
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
200mA
Power (watts)
3W
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
388-BBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Circuits
-
Other names
PEB20256E-V21
PEB20256E-V21IN

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB20256E-V21
Manufacturer:
MAX
Quantity:
63
Part Number:
PEB20256E-V21
Manufacturer:
Infineon Technologies
Quantity:
10 000
28/16
MFLE
MFL
MBIM
PBIM
RBIM
RFIM
Data Sheet
IIP will be asserted. When IIP is deasserted system software can reset
SRST to ’0’ to start normal operation again.
0
1
Select 28/16-port mode
This bit switches between the 28-port mode and the 16-port mode.
0
1
Maximum Frame Length Check Enable
0
1
Maximum Frame Length
MFL defines the maximum length of incoming data packets. Packets
exceeding the specified length are reported in the status field of the
receive descriptor and if selected in an additional channel interrupt.
Mailbox Interrupt Vector Mask
This bit enables or disables mailbox system interrupt vectors generated
by the mailbox.
0
1
PCI Bridge Interrupt Vector Mask
This bit enables or disables the ’PCI Access Error’ interrupt vector
generated by the PCI bridge.
0
1
Receive Buffer Interrupt Vector Mask
This bit enables or disables system interrupt vectors ’Receive Buffer
Queue Early Warning’ and ’Receive Buffer Action Queue Early Warning’
which are generated by the receive buffer. RBIM is valid only if bit RBM
is set.
0
1
Receive Buffer Failed Interrupt Vector Mask
This bit enables or disables the ’Receive Buffer Access Failed’ interrupt
vector.
0
Normal operation
Start software reset.
Switch to 16-port mode.
Switch to 28-port mode.
Disable maximum frame length check.
Enable maximum frame length check.
Enable interrupt vector.
Disable interrupt vector.
Enable interrupt vector.
Disable interrupt vector.
Enable interrupt vector.
Disable interrupt vector.
Enable interrupt vector.
162
Register Description
PEB 20256 E
PEF 20256 E
04.2001