Operation
H Cam Outputs and Control I/O Signal Monitoring (RUN Mode)
Note The 3F88L-160 (16-point model) Cam Positioner does not have cam outputs 17 to 32. (The relevant
D Procedure
D Cam Output Monitor Display
o (%)
Function No.
• • • • SPEED/ON
Keys other
than
Operation
indicators will remain OFF.)
BANK/
FUN
CAM/
PRMTR
CAM/
PRMTR
1
2
Parameter No.
Display
Cam output
monitor
Control I/O sig-
nal monitor
Function
name
(Displayed in normal RUN mode.)
Press the Bank/Function Key.
The Bank/Function display will show “0” and the
Cam/Parameter No. display will show “1.”
The ON/OFF status of cam outputs will be shown in the
SPEED/ON and POSITION/OFF displays.
Press the Cam/Parameter Key.
The Cam/Parameter No. display will show “2,” and the ON/OFF
status of the control I/O signals will be shown in the
SPEED/ON and POSITION/OFF displays.
Press any key other than the Cam/Parameter Key to return to
the display for normal RUN mode.
ON/OFF state of cam outputs 1 to 32 (see note) will be
displayed by lighting or not lighting each one of the
7-segment indicators (lit when cam is OFF).
ON/OFF state of control I/O signals (see note) will be
displayed by lighting or not lighting each one of the
7-segment indicators (lit when signal is OFF).