Operation
D Procedure
3-94
ON/
OFF
Operation
BANK/
FUN
CAM/
PRMTR
CAM/
PRMTR
CAM/
PRMTR
CLR
SET
ON/
OFF
+
SET
Display
Use the mode selection switch to change to PRGM mode.
Use the Bank/Function Key to display the bank number for the trial
operation.
Press the Set Key while pressing the ON/OFF Switching Key
The trial operation function is now enabled.
Note
Note
Press the Cam/Parameter Key.
The cam number will appear in the Cam/Parameter No. display.
The ON angle for step 1 will appear (flashing) in the SPEED/ON
display. The OFF angle for step 1 will appear (lit) in the
POSITION/OFF display.
Press the Cam/Parameter Key to set the cam number for which angle
data is to be adjusted.
The ON and OFF angles for step 1 will be displayed (ON angle
flashing, OFF angle lit)
Press the Up and Down Keys to increase or decrease the ON angle.
The ON angle for cam outputs will be changed at the same time.
Note The Up and Down Keys will not work if the ON section overlaps
Press the ON/OFF Switching Key to make the OFF angle flash. Use
the Up and Down Keys to increase and decrease the OFF angle. (The
cam output OFF angles will be changed at the same time.)
Note The Up and Down Keys will not work if the ON section overlaps
Press the Set Key to display step 2.
Repeat the same procedure to adjust the ON and OFF angles for step
2 onwards.
Note
Note
Press the Cam/Parameter Key to adjust other cam numbers.
Step 1 of the next cam number will be displayed.
Repeat the same procedure to adjust the angles for each step.
Press the Clear Key to exit the trial operation function.
Note To adjust the cams in another bank number, exit the trial operation,
another step.
another step.
press the Bank/Function Key to set the next bank number to be ad-
justed, and re-enter trial operation mode.
1. Press the Clear Key at this stage to return to the previous sta-
2. From this point, cam outputs corresponding to the Resolver
1. The display will not move on to step 2 if there is only one step.
2. During trial operation, the data changes will be reflected in the
tus.
angle will be output.
outputs and cam program at the point the changes are made.
Explanation