3F88L-CG001N Omron, 3F88L-CG001N Datasheet - Page 151

no-image

3F88L-CG001N

Manufacturer Part Number
3F88L-CG001N
Description
CABLE CAM OUTPUT-I/O BLOCK 1M
Manufacturer
Omron
Datasheet

Specifications of 3F88L-CG001N

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
3F88LCG001N
Communications
H Connecting to Host CPU
Connect the Cam Positioner to the host CPU through the communications port.
H Communications Specifications
The communications specifications of the Cam Positioner are shown below. Set the communications
conditions of the host CPU to these specifications.
Note 1. The Cam Positioner is factory-set to a baud rate of 9,600 bps. To use 19,200 bps, relevant
SET
(Slave
(
Unit set-
ting)
Mode
Communications method: RS-232C
Synchronization method: Start-stop synchronization
Baud rate:
Transmission code:
Data bit length:
Stop bit:
Parity:
Node number:
Subaddress:
Host CPU (such as personal
computers and CS1-series
Programmable Controllers)
parameters must be set. Refer to 3-6-13 Copy Function (Data Transfer) for details.
Read/Write
Program
Clear
Parameter
Clear
Parameter
Update
Function
Resolution/com-
pensation settings
Compensation val-
ues
Cam data protect
settings
Output hold infor-
mation
Cam program
---
---
---
ASCII
7 bits
Even
“00”
“00”
9,600 or 19,200 bps (parameter setting)
2 bits
Data
RS-232C cable
Reads and writes operation parame-
ters.
Reads and writes compensation value
parameters.
Reads and writes cam data protect
settings.
Reads and writes output hold informa-
tion.
Reads and writes cam programs.
Clears cam programs.
Returns parameters to their default
settings.
Enables parameters that will be made
valid when the power is turned OFF
and then ON. (Using this command
makes it unnecessary to turn the pow-
er OFF and then ON when making pa-
rameter settings valid.)
Communications capabilities
Communications
port
3F88L-160/162 Cam Positioner
Parameter Area
Read/Write
Command name
Chapter 4
/
4-3