3F88L-CG001N Omron, 3F88L-CG001N Datasheet - Page 40

no-image

3F88L-CG001N

Manufacturer Part Number
3F88L-CG001N
Description
CABLE CAM OUTPUT-I/O BLOCK 1M
Manufacturer
Omron
Datasheet

Specifications of 3F88L-CG001N

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
3F88LCG001N
Design
D Terminal Functions
Note 1. Use M3.5 round crimp terminals for AC 1/L and AC 2/N terminals.
Note 2. Use M3.5 round or forked crimp terminals for function earth and protect earth terminals.
Note If the power supply voltage of the Cam Positioner slowly increases or decreases at less than 85%
H Control Input Wiring
D Wiring Method
Main circuit power supply
input terminal
input terminal
Function earth terminal
Protect earth terminal
Terminal name
of the rated voltage (i.e., less than 85 V), operation may stop intermittently. If this affects the op-
eration of equipment, provide protective circuits that interrupt output enough to cause the voltage
to increase to more than 85% of the rated value.
24 V DC
• • • • Round crimp terminal
7 mm max.
AC1/L
AC2/N
Symbol
Inputs the AC power supply for the Cam
Positioner. Provide a 100 to 240 V AC
Positioner. Provide a 100 to 240 V AC
50/60 Hz power supply. (Rated power
supply voltage 85 to 264 V AC)
This is the primary ground terminal
connected for the power supply.
This is the frame ground terminal.
Function
Terminal screw size: M3
Tightening torque: 0.5 N S m
• • • • Forked crimp terminal
7 mm max.
1.25 mm
2.0 mm
2.0 mm
connection wire
Recommended
diameter
Chapter 2
2
2
2
2-17