Operation
H Cam Program Confirmation (PRGM Mode)
D Procedure
Operation
Once a cam program has been created, check that it has been created correctly.
BANK/
FUN
CAM/
PRMTR
CAM/
PRMTR
SET
SET
SET
Display
Use the mode selection switch to set to PRGM mode.
The data for step 1 of the bank and cam numbers displayed
will be displayed.
Note If there is no data, the display will be “-- -- --.”
Use the Bank/Function Key to set the bank number to be
checked.
The Bank/Function display will change as shown below each
time the Bank/Function Key is pressed.
1→2→3→4→5→6→7→8→1 etc.
Keep pressing the Bank/Function Key until the bank number to
be checked appears.
Note When the resolution is set to 720 (divisions/rotation), the
Use the Cam/Parameter Key to set the cam number to be
checked.
The Cam/Parameter No. display will change as shown below
when the Cam/Parameter Key is pressed.
1→2→3→...→15→16→1→ etc.
Keep pressing the Cam/Parameter Key until the cam number
to be checked is displayed.
Note For the 3F88L-162 (32-point model) Cam Positioner, the
Press the Set Key to display the data for the next step.
The display will be “-- -- --” for the last step.
If the Set Key is pressed while the display shows “-- -- --,” the
data for step 1 will be displayed again.
Press the Cam/Parameter Key to check the contents of other
cam numbers.
The data for step 1 of the bank and cam number displayed will
be displayed.
Note If there is no data, the display will be “-- -- --.”
Press the Set Key to check data for step 2.
display will not include 5→6→7→8.
numbers displayed will continue to “32” and then return
to “1.”
Explanation
Chapter 3