Appendix
7-6
Note The “F” mark in the cam output column indicates that cam outputs are turned OFF regardless of
7-16
E-00
E-01
Error
code
the output hold settings. The “f” mark indicates that if output hold is set, the output status immedi-
ately before the error was generated will be maintained. If output hold is not set, cam outputs will
be turned OFF. (Refer to 3-6-9 Output Hold Function for information.)
Error Codes
Hardware
failure
Power
interruption
during
programming
Error name
Memory
read/write
check error
when power
turned ON.
Power turned
OFF while
program being
edited.
Description
F
F
output
Cam
Malfunction
due to noise
(system
recovers when
power is
turned ON
again.)
The Cam
Positioner is
malfunctioning
(system does
not recover
when power is
turned ON
again.)
Power turned
OFF while
program being
edited.
RESET input
turned ON
while program
being edited.
RESET input
turned ON due
to noise while
program being
p g
edited.
di d
Probable
cause
g
Check if noise has
been generated
when or after the
power was turned
ON and take
appropriate
countermeasures
against the noise.
Replace the Cam
Positioner.
Check that the
voltage supplied to
the Cam Positioner
meets the
specifications (85 to
264 V AC) and
adjust if necessary.
Adjust the RESET
input sequence.
Find the source of
the noise and take
appropriate
countermeasures.
Check and adjust the
wiring for control
input signals.
Possible solution
Chapter 7
Turn the
power ON
again.
---
Change to
PRGM or SET
mode and
press the
Clear Key to
clear the error.
Then re-input
the cam
program.
Error reset
method
p