Operation
3-6-3 Parameter Explanation and Operation
H Explanation
In this section, individual parameters will be explained in the following format.
• • • • Parameter Name
• • • • Function Level Setting
• • • • Function No.
• • • • Parameter No.
• • • • Setting Range
• • • • Function Explanation
• • • • Additional Information
H Items to be Checked before Setting Parameters
The functions and parameter setting for 3F88L-160/162 Cam Positioners will be explained in the next
section. Before proceeding, be sure to check that the following two settings have been made.
• Set the function level (Function No. U) to “2” (function level 2).
• Set the resolution selection (Function No. A) to the resolution to be used.
Once these settings have been made, turn OFF the Cam Positioner and then turn it ON again.
If additional parameters are set without the power being turned OFF and then ON again, the function
levels and resolution selections will not be enabled and the parameters, therefore, will not be set proper-
ly.
D Origin Compensation Value
• (Function explanation)
Note (Additional information)
Function
No.
Parameter names such as “origin compensation value” and “backlash compensation value” will ap-
pear here.
The function level at which this parameter can be set will appear here.
In the above example, this parameter can be set at function level 2 (all functions) only.
The function number of this parameter will appear here.
The 7-segment indicator display will appear in parentheses after function numbers that appear as
letters (rather than numerals).
The parameter number for this parameter will appear here.
The setting range for this parameter will appear here.
The functions and factory settings for this parameter will be explained here.
Additional information for items with “See note” as well as information on restrictions or cautions
pertaining to the use of that function will appear here.
b (
Parameter name
b
)
Parameter
No.
1
Setting range 0 to 359 (0 to 719) (see note 1)
Function level setting
Function level
Chapter 3
3-49
2