Outline
1-1
1-1-1 Basic Operation
• Input a cam program (the ON/OFF pattern for cam outputs) into the Cam Positioner, use the bank
1-1-2 Resolution
• The angle resolution can be set to 360 (divisions/revolution) or 720 (divisions/revolution).
• The following table shows how functions and performances are affected by resolution settings.
Note For example, to set the ON angle at 90°, the setting is “90” for a 360 resolution and “180” for a 720
1-2
Angle setting and display units
Permissible Resolver speed
No. of cam program steps
Number of banks
switching signal to select the bank number, and turn ON the operation signal to start operation.
(Programming example for 360 resolution)
Cam No.
Function or Characteristic
Cam Program (Bank No. 1)
Cam Program (Bank No. 2)
resolution.
Cam Program (Bank No. 3)
1
2
2
3
---
The 3F88-L160 and 3F88L-162 Cam Positioners are Units that detect angles through a
Resolver (a sensor that detects absolute angles) and turn output signals ON and OFF at
a preset angle through a cam program.
The 3F88L-160 Cam Positioner has 16 cam output points and the 3F88L-162 Cam Posi-
tioner has 32 cam output points.
Functions
Step ON angle OFF angle
1
1
2
1
---
Resolver angle
Cam output 1
Cam output 2
Cam output 3
---
90
315
135
0
---
---
180
45
225
45
---
1° is set and displayed as “1.”
1,600 r/min
180 max.
8
90°
Cam Positioner
360 resolution
Bank switching signal (Bank numbers 1 to 3)
Operation signal (START)
Cam output
Control input
180°
270°
0.5° is set and displayed as “1.”
800 r/min
360 max.
4
Resolver
720 resolution
Chapter 1
User ma-
chine or