3F88L-CG001N Omron, 3F88L-CG001N Datasheet - Page 22

no-image

3F88L-CG001N

Manufacturer Part Number
3F88L-CG001N
Description
CABLE CAM OUTPUT-I/O BLOCK 1M
Manufacturer
Omron
Datasheet

Specifications of 3F88L-CG001N

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
3F88LCG001N
Outline
1-5
1-5-1 Before Operation
H Basic Use
• The procedure for using the Cam Positioner at function level 1 (basic operation/monitor only) is out-
Note This procedure is applicable when only the basic functions (function level 1) are used. In the
Installation
Wiring
Power ON
Function level selection
Initial settings
Power resetting (OFF to
ON)
Creation and confirmation
of cam programs
Connection between
Resolver and machinery
Execution of origin
compensation
Operation/monitoring
Function level selection
lined below.
cases outlined below, the applied functions (function level 2) must be used. (Refer to 3-6 Applied
Functions.)
S When setting origin compensation values, using backlash compensation, advance angle com-
S When executing a trial or compensation operation.
Procedure
pensation, and other compensation functions.
Operation Procedure
Install the Cam Positioner according to the installation
environment conditions.
Connect the wiring for the power supply, Resolver, and
peripheral devices.
Before the power is turned ON:
• Check that the wires and connectors for the Resolver and
• Check that the Resolver and the machinery are not con-
After the power is turned ON:
• Check that there are no error codes displayed (E--**).
• Set the mode selection switch to RUN and check that the
Select function level 1 (basic operation/monitor only).
Set the resolution (SET mode) and rotation direction
(CW/CCW) to suit the application.
Turn ON the power to enable the set parameters.
Create and check cam programs (PRGM mode).
Check the number of programs (SET mode).
Turn OFF the power and connect the Resolver and the
machinery.
Turn ON the power and execute origin compensation (use
the ADJ switch in SET mode).
Change to RUN mode and check the operation of the
machinery and monitor the I/O status. Correct the cam
program if required (PRGM mode).
If required, set to function level 0 (monitor only) to prevent
faulty operation.
peripheral devices have been connected properly.
nected.
number of revolutions and the present angle display changes
when the Resolver axis is rotated by hand.
Contents
2-2
2-3
3-5-1
3-5-2
3-5-3
3-5-4
3-5-5
3-5-6
3-4
Chapter 1
Reference
section
1-11