Operation
The cam program is now complete.
Note 1. If there is an error with the input data, the display will change as outlined below. Check and
Note 2. Cam outputs turn ON at the set ON angle and turn OFF at the set OFF angle. In this cam pro-
3-30
Operation
S If data is duplicated in the ON region (the region between an ON angle and OFF angle) of a
S If the input numeric data exceeds the setting range.
SET
SET
ON/
OFF
ON/
OFF
reset the input data.
step that has been already input.
gram example, the cam output number 2 will turn ON at the point when 0° is detected and turn
OFF when 90° is detected.
“E-22” (cam program duplication error) will appear in the SPEED/ON angle display. Press
the Clear Key to clear the error and reset with the correct data.
All displays will flash twice and return to the status before the data was edited. Reset with the
correct data.
Display example
In step 2 of cam number 3, set the ON angle to “150” and the
OFF angle to “180.”
The setting method is the same as outlined previously.
Press the Set Key to save the ON and OFF angle settings for
step 2.
When the Set Key is pressed, the data will stop flashing for
approximately one second.
Step 3 can be input approximately one second after the Set
Key has been pressed.
In step 3 of cam number 3, set the ON angle to “270” and the
OFF angle to “300.”
The setting method is the same as outlined previously.
Press the Set Key to save the ON and OFF angle settings for
step 3.
When the Set Key is pressed, the data will stop flashing for
approximately one second.
Step 4 can be input approximately one second after the Set
Key has been pressed.
Explanation
Chapter 3