3F88L-CG001N Omron, 3F88L-CG001N Datasheet - Page 114

no-image

3F88L-CG001N

Manufacturer Part Number
3F88L-CG001N
Description
CABLE CAM OUTPUT-I/O BLOCK 1M
Manufacturer
Omron
Datasheet

Specifications of 3F88L-CG001N

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
3F88LCG001N
Operation
• When the backlash compensation enable/disable setting (Function No. H, Parameter No. 1) is dis-
• Use the Up and Down Keys to change the data.
• When the Set Key is pressed, the data will remain lit for approximately one second, the setting will be
3-6-6 Advance Angle Compensation
H Functions
• The advance angle compensation function advances the ON and OFF angles for all cams in propor-
• When cam output signals are used to move peripheral devices, this function is used to adjust the tim-
• There are three advance angle compensation parameters for 3F88L-160/162 Cam Positioners.
• The advance angle compensation function operates when the “advance angle compensation enable/
3-62
played, the current settings will be flashing in the SPEED/ON display.
confirmed, and then the data will resume flashing.
tion to the speed of the Resolver.
ing of peripheral device movement. This function can also be used to minimize angle deviation caused
by a delay in signal transmission.
disable setting” parameter is set to “enable.”
Advance angle compensation value 1: Speed and angle data settings
Advance angle compensation value 2: Speed and angle data settings
Advance angle compensation value 3: Angle data settings for advance angle compensation posi-
tion
The relationship between the Resolver speed and advance angle is set in the first two parameters,
advance angle compensation values 1 and 2. The third parameter, advance angle compensation
value 3 indicates the position where the advance angle is to be changed. (For example, if the ad-
vance angle amount changes from 0° to 1°, the angle must be increased by 1° somewhere in the
rotation. This parameter designates the position for that increase.)
Chapter 3