3F88L-CG001N Omron, 3F88L-CG001N Datasheet - Page 217

no-image

3F88L-CG001N

Manufacturer Part Number
3F88L-CG001N
Description
CABLE CAM OUTPUT-I/O BLOCK 1M
Manufacturer
Omron
Datasheet

Specifications of 3F88L-CG001N

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
3F88LCG001N
Appendix
E-02
E-10
E-11
Error
code
Power failure
during write to
non-volatile
memory
Resolver
disconnection
error
Sum check
error in
program
memory
Error name
Power turned
OFF during
data save to
non-volatile
memory.
Resolver cable
disconnected
during
teaching or
trial operation
in RUN mode
or error in
Resolver
interface
interface
circuit.
Memory sum
check error
when power
turned ON.
Description
i l
g
i
F
F
F
output
Cam
Power turned
OFF while
writing to
memory.
RESET input
turned ON
while writing to
memory.
RESET input
turned ON due
to noise while
writing to
memory.
Resolver
connector has
been
disconnected.
Resolver
connector
connection
imperfect.
Resolver cable
disconnected.
Resolver
detection
circuit error.
Malfunction
due to noise
(system
recovers when
power is
turned ON
again.)
The Cam
Positioner is
malfunctioning
(system does
not recover
when power is
turned ON
again.)
Probable
cause
g
Check that the
voltage supplied to
the Cam Positioner
meets the
specifications (85 to
264 V AC) and
adjust if necessary.
Adjust the RESET
input sequence.
Find the source of
the noise and take
appropriate
countermeasures.
Check and adjust the
wiring for control
input signals.
Check that the
Resolver connector
is connected
securely.
Replace the
Resolver cable.
Replace the Cam
Positioner.
Check if noise has
been generated
when or after the
power was turned
ON and take
appropriate
countermeasures
against the noise.
Replace the Cam
Positioner.
Possible solution
y
Chapter 7
Change to
PRGM or SET
mode and
press the
Clear Key to
clear the error.
Then re-input
the cam
program.
Change to
PRGM or SET
mode and
press the
p
Cl
Clear Key to
clear the error.
---
Turn ON the
power again.
---
Error reset
method
K
p
7-17