Operation
D Procedure
Note These functions are enabled once the power has been turned OFF and then ON again.
Operation
BANK/
FUN
BANK/
FUN
SET
SET
Display
Use the mode selection switch to change to SET mode.
Keep pressing the Bank/Function Key until “A” appears on the
Bank/Function display.
Note The display for level 1 will change from “1” to “2” through
Press the Set Key to enable settings to be made.
Cam/Parameter number display: “1”
SPEED/ON angle display: Flashes current setting
Press the Up or Down Keys and select the resolution to be
used.
0: 360 (divisions/rotation)
1: 720 (divisions/rotation)
Press the Set Key to confirm the settings.
The setting will stop flashing for approximately 1 second and
then resume flashing.
Note When a setting is flashing, the Up and Down Keys are
Press the Bank/Function Key.
The display will return to only the function number appearing.
Turn OFF the power supply. (The settings will now be enabled.)
to “8” then to “A,” “t,” “U,” and back to “1” and so on.
(When the resolution is set to 720, “5” through “8” will
not be displayed.)
enabled and the setting can be changed.
Explanation
Chapter 3
3-23