High-density I/O Units
(Special I/O Units)
Expanded System Configurations
2-4
2-4-1 Required Mounting Conditions
2-4-2 Special I/O Units
High-speed Counter Units
Position Control Units
(C200H-NC111/112,
C200HW-NC113/213)
ASCII Units
Analog I/O Units
ID Sensor Units
Fuzzy Logic Units
4 units max.
Expanded System Configurations
A
Note
High-density and Mixed I/O
Units
Temperature Control Units
Cam Positioner Units
Heat/Cool Temperature
Control Unit
PID Control Unit
8 units max.
A maximum of 16 Special I/O Units including PC Link Units can be mounted to
any slot of CPU, Expansion I/O, and Slave Racks. I/O word numbers 100 to 199,
400 to 459, and DM 1000 to DM 2599 are allocated to each Special I/O Unit.
High-density I/O Units can be mounted Remote I/O Slave Units only when the
Remote I/O Slave Units are connected to C200H-RM001-PV1 or
C200H-RM201 Remote I/O Master Units.
The number of Special I/O Units used with a Slave Rack is limited by data trans-
mission considerations, as shown in the table below. The numbers in the table
indicate the maximum number of Units of groups A, B, C, or D which can be used
with a single Slave Rack.
It is possible to connect a variety of Special I/O Units to the C200HX/
C200HG/C200HE Racks.
The TTL Input Unit, DC Input Unit, TTL Output Unit, Transistor Output Unit, TTL
I/O Unit, and DC Input/Transistor Output Unit are High-density I/O Units.
The C200H-ID501, C200H-OD501, and C200H-MD501 are I/O Units for the
TTL Unit.
Eight input points each of the C200H-ID501, C200H-ID215, C200H-MD501,
C200H-MD115, and C200H-MD215 can be set for pulse input.
A High-density I/O Unit can retrieve pulse input, which is shorter in length than
that of the High-density I/O Unit cycle time, as an input signal when the High-
density I/O Unit is set for pulse input.
1. When a combination of Units from groups A, B, C, and D is used, the number
2. Other Units can be added until the total number of Units reaches ten. If PC
from each group must satisfy both the following equations:
3A + B + 2C + 6D ≤ 12
A + B + C + D ≤ 8
Link Units are used, the number of Units including the PC Link Units must
not exceed ten.
B
Temperature Sensor Units
Voice Units
6 units max.
C
Position Control Units
(C200H-NC211,
C200HW-NC413)
Motion Control Units
2 units max.
Section 2-4
D
33