C200HW-PA204C Omron, C200HW-PA204C Datasheet

no-image

C200HW-PA204C

Manufacturer Part Number
C200HW-PA204C
Description
Power Supply
Manufacturer
Omron
Datasheet

Specifications of C200HW-PA204C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Power Supply Units with
Maintenance Forecast Monitor
for SYSMAC PLCs
CJ Series: CJ1W-PA205C
CS Series or C200HX/HG/HE: C200HW-PA204C
New PLC Power Supply Units That Let You Know
When Unit Replacement Is Necessary
CJ Series:
CJ1W-PA205C
CS Series or
C200HX/HG/HE:
C200HW-PA204C

Related parts for C200HW-PA204C

C200HW-PA204C Summary of contents

Page 1

... Power Supply Units with Maintenance Forecast Monitor for SYSMAC PLCs CJ Series: CJ1W-PA205C CS Series or C200HX/HG/HE: C200HW-PA204C New PLC Power Supply Units That Let You Know When Unit Replacement Is Necessary CJ Series: CS Series or CJ1W-PA205C C200HX/HG/HE: C200HW-PA204C ...

Page 2

... OFF and you have six months to replace the Power Supply Unit. Same Wiring and Size as Current Power Supply Units Simply replace your current Power Supply Unit to add the maintenance forecast monitor function. The CJ1W-PA205C is the same size as the CJ1W-PA205R and the C200HW-PA204C is the same size as the C200HW-PA204. CJ Series ...

Page 3

... Go ahead and replace it. Six months remain when "0.0" and "A02" alternate. Reasonable number of spare Power Supply Units Reasonably sized Routine Check of PLC inventory Power Supply Units Indication Rack Model 04-12-01 A1 CJ1W-PA205C FUL A2 CJ1W-PA205C HLF B1 C200HW-PA204C 0.5 3 ...

Page 4

... The Power Supply Unit must be stored at an ambient temperature of –25 to 30˚C and a humidity of 25% to 70% to maintain the maintenance forecast monitor function when the Unit is stored without power supplied for more than three months aintenance orecast C200HW-PA204C C200HW-PA204C POWER Monitor display (7- segment, red) TEST 4 ...

Page 5

... N ames and D imensions C200HW-PA204C Maintenance Forecast Monitor Display Module PA204C C200HW-PA204C POWER 130 Years TEST Wiring connections (open cover) 54 • AC inputs: 100 to 240 V AC (50/60 Hz) power supply • LG: Use a separate ground to 100 Ω or less to improve resistance to electric shock and noise. ...

Page 6

... N and Lloyd (approval pending) Note: The Power Supply Unit must be stored at an ambient temperature of –25 to 30°C and a humidity of 25% to 70% to maintain the maintenance forecast monitor function when the Unit is stored without power supplied for more than three months. 6 C200HW-PA204C 100 VA max DC total 2 ...

Page 7

... Input specifications 100 to 240 V AC (wide range) Power interruption detection 85 V max. voltage Service power supply None RUN output None Terminal block arrangement C200HW-PA204C AC input Alarm output (maintenance forecast monitor output) Unused terminals Power indicator On the maintenance forecast monitor display module ...

Page 8

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 9

... São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS MEXICO • HEAD OFFICE Apodaca, N.L. • 52.811.156.99.10 • 001.800.556.6766 • mela@omron.com OMRON EUROpE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu Cat. No. R130-E1-01 01/05 OMRON ARGENTINA • ...