Indicator Operation
The indicators depend on the model of B7A Interface Unit, as shown below.
I/O Number Setting
The setting of the I/O number determines the words allocated to the Interface Unit. Set the I/O number to between
0 and 9.
Note 1. Turn off the power supply to the PC before changing the I/O number setting. Any new setting will not be
ERROR 1
ERROR 2
ERROR
3ms
LOAD OFF
15IN+ERR
2. Use a flat-blade screw driver to change the I/O number setting. Be careful not to leave the switch halfway
effective until the next time the power supply is turned on.
between settings and be careful not to damage the switch.
Name
Input
transmission
error
Transmission
delay setting
Transmission
error process
Input mode
setting
Back
Red
Orange
Orange
Orange
Color
Lights when an error occurs in transmissions from an Input B7A Link Terminal.
For the B7A12/22, ERROR 1 is for the first word allocated to the B7A Interface
Unit; ERROR 2 is for the second word.
Lit when the transmission delay is set to the high-speed setting (3 ms).
Not lit when the transmission delay is set to the standard setting (19.2 ms).
Lit when the processing for transmission errors is set to reset input status.
Not lit when the processing for transmission errors is set to hold input status.
Lit when the input mode mode is set to use 15 inputs and 1 error input.
Not lit when the input mode mode is set to use 16 inputs.
DIP switch
Used to set the transmission delay,
transmission error processing mode, in-
put mode, and ERROR indicator opera-
tion.
Setting in direction
of notch
Function
Appendix B
205