101-1279 Rabbit Semiconductor, 101-1279 Datasheet - Page 91

PLASTIC ENCLOSURE FOR BL4S100

101-1279

Manufacturer Part Number
101-1279
Description
PLASTIC ENCLOSURE FOR BL4S100
Manufacturer
Rabbit Semiconductor
Datasheet

Specifications of 101-1279

Accessory Type
Enclosure
Product
Prototyping Accessories
Processor Type
BL4S100
Board Size
146 mm x 96 mm x 16 mm
Interface Type
Ethernet
For Use With/related Products
BL4S100
Lead Free Status / RoHS Status
Not applicable / Not applicable
Other names
316-1159
FUNCTION DESCRIPTION
PARAMETER
RETURN VALUE
SEE ALSO
BL4S100 User’s Manual
float anaInmAmps(int channel);
brdInit, anaInConfig, anaIn, anaInDiff, anaInVolts, anaInCalib
Reads the state of a single-ended A/D converter input channel and uses the previously
set calibration constants to convert it to a floating-point current value in milli amps. The
nominal range is 0 mA to 20 mA, although it is possible to receive values outside this
range before a
channel
A current value corresponding to the current on the analog input channel, or a value of
BL_ERRCODESTART
A/D converter operation errors (will not create run-time error):
System errors (can create run-time error unless disabled):
BL_NOT_CAL
BL_OVERFLOW
BL_TIMEOUT
BL_WRONG_MODE
-ERR_ANA_CALIB
-ERR_ANA_INVAL
BL_OVERFLOW
— A/D converter is not calibrated for this channel/gain.
— A/D converter timeou.t
— A/D converter overflow.
A/D converter input channel (0–3 corresponding to AIN0–AIN3)
or less to indicate an error condition:
— A/D converter is in wrong mode (run
— fault detected in reading calibration factor.
— invalid parameter value.
error is returned.
anaInmAmps
anaInConfig()
).