3.4.1 A/D Converter Calibration
When you start to develop your application, run
SAMPLES\UserBlock
vertently write over them while running the sample programs.
To get the best results from the A/D converter, it is necessary to calibrate each mode
(single-ended, differential, and current) for each of its gains. It is imperative that you cali-
brate each of the A/D converter inputs in the same manner as they are to be used in the
application. For example, if you will be performing floating differential measurements or
differential measurements using a common analog ground, then calibrate the A/D con-
verter in the corresponding manner. The calibration table in software only holds calibra-
tion constants based on mode, channel, and gain.
be taken into account by calibrating using the same mode and gain setup as in the intended use.
Sample programs are provided to illustrate how to read and calibrate the various A/D
inputs for the three operating modes.
These sample programs are found in the
Section 4.2.3 for more information on these sample programs and how to use them.
BL4S100 User’s Manual
Single-Ended, unipolar
Differential, bipolar
4–20 mA
Mode
folder to save the factory calibration constants in case you inad-
ADC_RD_SE_UNIPOLAR.C ADC_CAL_SE_UNIPOLAR.C
ADC_RD_DIFF.C
ADC_RD_MA.C
ADC
Read
subdirectory in
USERBLOCK_READ_WRITE.C
Other factors affecting the calibration must
SAMPLES\BL4S1xx
ADC_CAL_DIFF.C
ADC_CAL_MA.C
Calibrate
in the
. See