P89V662FBC,557 NXP Semiconductors, P89V662FBC,557 Datasheet - Page 20

IC 80C51 MCU FLASH 32K 44-TQFP

P89V662FBC,557

Manufacturer Part Number
P89V662FBC,557
Description
IC 80C51 MCU FLASH 32K 44-TQFP
Manufacturer
NXP Semiconductors
Series
89Vr
Datasheet

Specifications of P89V662FBC,557

Program Memory Type
FLASH
Program Memory Size
32KB (32K x 8)
Package / Case
44-TQFP
Core Processor
8051
Core Size
8-Bit
Speed
40MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
POR, PWM, WDT
Number Of I /o
36
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Processor Series
P89V6x
Core
80C51
Data Bus Width
8 bit
Data Ram Size
1 KB
Interface Type
I2C/UART
Maximum Clock Frequency
40 MHz
Number Of Programmable I/os
36
Number Of Timers
3
Operating Supply Voltage
4.5 V to 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
622-1001 - USB IN-CIRCUIT PROG 80C51ISP
Eeprom Size
-
Data Converters
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
568-2435
935280832557
P89V662FBC

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P89V662FBC,557
Manufacturer:
Maxim
Quantity:
260
Part Number:
P89V662FBC,557
Manufacturer:
NXP Semiconductors
Quantity:
10 000
NXP Semiconductors
P89V660_662_664_3
Product data sheet
based on the oscillator frequency. The ISP feature requires that an initial character (an
uppercase U) be sent to the P89V660/662/664 to establish the baud rate. The ISP
firmware provides auto-echo of received characters. Once baud rate initialization has
been performed, the ISP firmware will only accept Intel Hex-type records. Intel Hex
records consist of ASCII characters used to represent hexadecimal values and are
summarized below:
In the Intel Hex record, the ‘NN’ represents the number of data bytes in the record. The
P89V660/662/664 will accept up to 32 data bytes. The ‘AAAA’ string represents the
address of the first byte in the record. If there are zero bytes in the record, this field is often
set to 0000. The ‘RR’ string indicates the record type. A record type of ‘00’ is a data
record. A record type of ‘01’ indicates the end-of-file mark. In this application, additional
record types will be added to indicate either commands or data for the ISP facility.
The maximum number of data bytes in a record is limited to 32 (decimal). ISP commands
are summarized in
information in the record is stored internally and a checksum calculation is performed. The
operation indicated by the record type is not performed until the entire record has been
received. Should an error occur in the checksum, the P89V660/662/664 will send an ‘X’
out the serial port indicating a checksum error. If the checksum calculation is found to
match the checksum in the record, then the command will be executed. In most cases,
successful reception of the record will be indicated by transmitting a ‘.’ character out the
serial port.
Table 11.
Record type
00
01
02
:NNAAAARRDD..DDCC<crlf>
ISP hex record formats
Command/data function
Program User Code Memory
:nnaaaa00dd..ddcc
Where:
nn = number of bytes to program
aaaa = address
dd..dd = data bytes
cc = checksum
Example:
:09000000010203040506070809CA
End of File (EOF), no operation
:xxxxxx01cc
Where:
xxxxxx = required field but value is a ‘don’t care’
cc = checksum
Example:
:00000001FF
not used
Table
Rev. 03 — 10 November 2008
11. As a record is received by the P89V660/662/664, the
80C51 with 512 B/1 kB/2 kB RAM, dual I
P89V660/662/664
© NXP B.V. 2008. All rights reserved.
2
C-bus, SPI
20 of 89

Related parts for P89V662FBC,557