PEB3086HV14XP Infineon Technologies, PEB3086HV14XP Datasheet - Page 175

no-image

PEB3086HV14XP

Manufacturer Part Number
PEB3086HV14XP
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB3086HV14XP

Control Interface
HDLC
Lead Free Status / Rohs Status
Compliant
ISAC-SX
PEB 3086
Detailed Register Description
a two-byte address field, it contains the value of the second programmable Terminal
Endpoint Identifier according of the ISDN LAPD-protocol.
In non-auto-modes with one-byte address field, TEI2 is a response address, according
to X.25 LAPD.
EA2 ... Address field Extension bit
This bit is to be set to ’1’ according to HDLC/LAPD.
4.1.16
RSTAD - Receive Status Register D-Channel
Value after reset: 0F
H
7
0
RSTAD
VFR
RDO
CRC
RAB
SA1
SA0
C/R
TA
RD (28)
For general information please refer to
Figure
.
VFR... Valid Frame
Determines whether a valid frame has been received.
The frame is valid (1) or invalid (0).
A frame is invalid when there is not a multiple of 8 bits between flag and frame end (flag,
abort).
RDO ... Receive Data Overflow
If RDO=1, at least one byte of the frame has been lost, because it could not be stored in
RFIFOD. As opposed to the ISTAD.RFO an RDO indicates that the beginning of a frame
has been received but not all bytes could be stored as the RFIFOD was temporarily full.
CRC ... CRC Check
The CRC is correct (1) or incorrect (0).
RAB ... Receive Message Aborted
The receive message was aborted by the remote station (1), i.e. a sequence of seven
1’s was detected before a closing flag.
Data Sheet
175
2003-01-30

Related parts for PEB3086HV14XP