HD6437101 RENESAS [Renesas Technology Corp], HD6437101 Datasheet - Page 266

no-image

HD6437101

Manufacturer Part Number
HD6437101
Description
32-Bit RISC Microcomputer
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6437101A01FV
Manufacturer:
RENESAS
Quantity:
370
Part Number:
HD6437101A01FV
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6437101A01FV
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6437101A01FV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Company:
Part Number:
HD6437101A01FV
Quantity:
596
Part Number:
HD6437101A03FV
Manufacturer:
RENESAS
Quantity:
1 426
Part Number:
HD6437101A03FV
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6437101A05FV
Quantity:
24 070
Part Number:
HD6437101A05FV
Manufacturer:
RENESAS
Quantity:
1 000
Section 8 Multifunction Timer Pulse Unit (MTU)
8.7.18
When making a transition from channel 3 or 4 normal operation or PWM mode 1 to reset-
synchronous PWM mode, if the counter is halted with the output pins (TIOC3B, TIOC3D,
TIOC4A, TIOC4C, TIOC4B, TIOC4D) in the high-impedance state, followed by the transition to
reset-synchronous PWM mode and operation in that mode, the initial pin output will not be
correct.
When making a transition from normal operation to reset-synchronous PWM mode, write H'11 to
registers TIOR3H, TIOR3L, TIOR4H, and TIOR4L to initialize the output pins to low level
output, then set an initial register value of H'00 before making the mode transition.
When making a transition from PWM mode 1 to reset-synchronous PWM mode, first switch to
normal operation, then initialize the output pins to low level output and set an initial register value
of H'00 before making the transition to reset-synchronous PWM mode.
8.7.19
When channels 3 and 4 are in complementary PWM mode or reset-synchronous PWM mode, the
PWM waveform output level is set with the OLSP and OLSN bits in the timer output control
register (TOCR). In the case of complementary PWM mode or reset-synchronous PWM mode,
TIOR should be set to H'00.
8.7.20
If module standby mode is entered when an interrupt has been requested, it will not be possible to
clear the CPU interrupt source. Interrupts should therefore be disabled before entering module
standby mode.
8.7.21
When cascade-connected timer counters (TCNT-1 and TCNT-2) are operated, cascade values
cannot be captured even if input capture is executed simultaneously with TIOC1A or TIOC1B and
TIOC2A or TIOC2B.
Rev.1.00 Sep. 18, 2008 Page 232 of 522
REJ09B0069-0100
Cautions on Transition from Normal Operation or PWM Mode 1 to Reset-
Synchronous PWM Mode
Output Level in Complementary PWM Mode and Reset-Synchronous PWM Mode
Interrupts in Module Standby Mode
Simultaneous Input Capture of TCNT-1 and TCNT-2 in Cascade Connection