HD6417706 RENESAS [Renesas Technology Corp], HD6417706 Datasheet - Page 427

no-image

HD6417706

Manufacturer Part Number
HD6417706
Description
Renesas 32-Bit RISC Microcomputer Super RISC engine Family/SH7700 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417706
Manufacturer:
TDK
Quantity:
500
Part Number:
HD6417706
Manufacturer:
TOSH
Quantity:
1 000
Part Number:
HD6417706-SH3-133V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706BP133
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706BP133V
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6417706F120DV
Manufacturer:
HITACHI
Quantity:
96
Part Number:
HD6417706F120DV
Manufacturer:
RENESAS/PBF
Quantity:
375
Part Number:
HD6417706F120DV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706F133
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706F133V
Manufacturer:
EDISON
Quantity:
2 000
Part Number:
HD6417706F133V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
HD6417706F133V
Quantity:
27
In receiving, the SCI operates as follows:
1. The SCI monitors the communication line. When it detects a start bit (0), the SCI synchronizes
2. Receive data is stored into the SCRSR in order from the LSB to the MSB.
3. The parity bit and stop bit are received. After receiving these bits, the SCI makes the following
Note: When a receive error flag is set, further receiving is disabled. The RDRF bit is not set to 1.
4. After setting RDRF to 1, if the receive-data-full interrupt enable bit (RIE) is set to 1 in the
Table 14.11 Receive Error Conditions and SCI Operation
Receive Error
Overrun error
Framing error
Parity error
internally and starts receiving.
checks:
a. Parity check: The number of 1s in the receive data must match the even or odd parity
b. Stop bit check: The stop bit value must be 1. If there are two stop bits, only the first stop bit
c. Status check: RDRF must be 0 so that receive data can be loaded from the SCRSR into the
SCSCR, the SCI requests a receive-data-full interrupt (RXI). If one of the error flags (ORER,
PER, or FER) is set to 1 and the receive-data-full interrupt enable bit (RIE) in the SCSCR is
also set to 1, the SCI requests a receive-error interrupt (ERI).
setting of the O/E bit in the SCSMR.
is checked.
SCRDR.
If these checks all pass, the SCI sets RDRF to 1 and stores the received data in the SCRDR.
If one of the checks fails (receive error), the SCI operates as indicated in table 14.11.
Be sure to clear the error flags.
Abbreviation
ORER
FER
PER
Condition
RDRF is still set to 1 in SCSSR
Stop bit is 0
Parity of receive data differs from
even/odd parity setting in SCSMR
Receiving of next data ends while
Rev. 4.00, 03/04, page 381 of 660
Data Transfer
Receive data not loaded
from SCRSR into
SCRDR
Receive data loaded from
SCRSR into SCRDR
Receive data loaded from
SCRSR into SCRDR