HD6417706 RENESAS [Renesas Technology Corp], HD6417706 Datasheet - Page 196

no-image

HD6417706

Manufacturer Part Number
HD6417706
Description
Renesas 32-Bit RISC Microcomputer Super RISC engine Family/SH7700 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417706
Manufacturer:
TDK
Quantity:
500
Part Number:
HD6417706
Manufacturer:
TOSH
Quantity:
1 000
Part Number:
HD6417706-SH3-133V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706BP133
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706BP133V
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6417706F120DV
Manufacturer:
HITACHI
Quantity:
96
Part Number:
HD6417706F120DV
Manufacturer:
RENESAS/PBF
Quantity:
375
Part Number:
HD6417706F120DV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706F133
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706F133V
Manufacturer:
EDISON
Quantity:
2 000
Part Number:
HD6417706F133V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
HD6417706F133V
Quantity:
27
4. When the DMAC data access is included in the break condition:
7.3.4
1. By specifying SEQ in BRCR is set to 1, the sequential break is issued when channel B break
2. In sequential break specification, logical or internal bus can be selected and the execution
7.3.5
The PC when a break occurs is saved to the SPC in user breaks. The PC value saved is as follows
depending on the type of break.
1. When instruction fetch (before instruction execution) is specified as a break condition:
2. When instruction fetch (after instruction execution) is specified as a break condition:
3. When data access (address only) is specified as a break condition:
4. When data access (address + data) is specified as a break condition:
Rev. 4.00, 03/04, page 150 of 660
When the data value is included in the break conditions, either longword, word, or byte is
specified as the operand size of the break bus cycle registers (BBRA and BBRB). When data
values are included in break conditions, a break is generated when the address conditions and
data conditions both match. To specify byte data for this case, set the same data in two bytes at
bits 15 to 8 and bits 7 to 0 of the break data register B (BDRB) and break data mask register B
(BDMRB). When word or byte is set, bits 31 to 16 of BDRB and BDMRB are ignored.
When the address is included in the break condition on DMAC data access, the operand size of
the break bus cycle registers (BBRA and BBRB) should be byte, word or no specified operand
size. When the data value is included, select either byte or word.
condition matches after channel A break condition matches. A user break is ignored even if
channel B break condition matches before channel A break condition matches. When channels
A and B condition match at the same time, the sequential break is not issued.
times break condition can be also specified. For example, when the execution times break
condition is specified, the break condition is satisfied at channel B condition match with BETR
= H'0001 after channel A condition match.
The value of the program counter (PC) saved is the address of the instruction that matches the
break condition. The fetched instruction is not executed, and a break occurs before it.
The PC value saved is the address of the instruction to be executed following the instruction in
which the break condition matches. The fetched instruction is executed, and a break occurs
before the execution of the next instruction.
The PC value is the address of the instruction to be executed following the instruction that
matched the break condition. The instruction that matched the condition is executed and the
break occurs before the next instruction is executed.
Sequential Break
Value of Saved Program Counter

Related parts for HD6417706