MC68HC908LK24 MOTOROLA [Motorola, Inc], MC68HC908LK24 Datasheet - Page 233

no-image

MC68HC908LK24

Manufacturer Part Number
MC68HC908LK24
Description
Microcontrollers
Manufacturer
MOTOROLA [Motorola, Inc]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68HC908LK24CFQ
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68HC908LK24CFQ
Manufacturer:
FRE/MOT
Quantity:
20 000
Part Number:
MC68HC908LK24CFU
Manufacturer:
FREESCALE Semiconductor
Quantity:
489
Part Number:
MC68HC908LK24CFU
Manufacturer:
FREESCALE
Quantity:
300
Part Number:
MC68HC908LK24CFU
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC68HC908LK24CFU
Manufacturer:
FREESCALE
Quantity:
300
Part Number:
MC68HC908LK24CFU
Manufacturer:
FREESCALE
Quantity:
168
Part Number:
MC68HC908LK24CPK
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
12.10.2 RTC Calibration Data Register (RTCCDAT)
MC68HC908LJ24/LK24 — Rev. 2
MOTOROLA
Address:
The RTC calibration data register (RTCCDAT) contains the RTC
calibration data.
EOVL — E Register Overflow
E[5:0] — RTC Compensation Value (E register)
Reset:
Read:
Write:
This read-only bit indicates that the time difference recorded between
CALIN and CGMXCLK after 15 seconds during the last automatic
calibration had exceeded 31 CGMXCLK cycles. Clear this flag by
writing to the E register after the CAL bit is set. Setting the AUTOCAL
bit will also clear this flag, but subsequent automatic calibration may
set this flag again.
E[5:0] is a two’s complement number which indicates the number of
CGMXCLK cycles the RTC requires to compensate for a 15 second
duration. If the compensation exceeds the limit of ±31 CGMXCLK
cycles, the E[5:0] bits remain at the maximum value of –30 (%100010)
or +30 (%011110), and the EOVL flag will be set.
When compensation is enabled (COMEN = 1): If E is negative, an E
number of cycles will be subtracted from the 491520 CGMXCLK
cycles (32768 × 15).
When compensation is enabled (COMEN = 1): If E is positive, an E
number of cycles will be added to the 491520 CGMXCLK cycles
(32768 × 15).
E[5:0] is written by the RTC compensation circuit during automatic
calibration (AUTOCAL = 1). User can only write to E{5:0] when
AUTOCAL = 0 and CAL = 1. Reset has no effect on E[1:0] bits.
Freescale Semiconductor, Inc.
For More Information On This Product,
Figure 12-7. RTC Calibration Data Register (RTCCDAT)
1 = E register overflow detected during the last automatic
0 = No E register overflow detected during last automatic
$0041
EOVL
calibration
calibration
U
Go to: www.freescale.com
Real Time Clock (RTC)
0
0
E5
U
E4
U
E3
U
E2
U
Real Time Clock (RTC)
E1
U
RTC Registers
Data Sheet
E0