SAM3S16C Atmel Corporation, SAM3S16C Datasheet - Page 68

no-image

SAM3S16C

Manufacturer Part Number
SAM3S16C
Description
Manufacturer
Atmel Corporation
Datasheet

Specifications of SAM3S16C

Flash (kbytes)
1024 Kbytes
Pin Count
100
Max. Operating Frequency
100 MHz
Cpu
Cortex-M3
# Of Touch Channels
39
Hardware Qtouch Acquisition
No
Max I/o Pins
79
Ext Interrupts
79
Usb Transceiver
1
Quadrature Decoder Channels
2
Usb Speed
Full Speed
Usb Interface
Device
Spi
3
Twi (i2c)
2
Uart
4
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
12
Adc Speed (ksps)
1000
Analog Comparators
1
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
12
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
128
Self Program Memory
YES
External Bus Interface
1
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
6
Input Capture Channels
6
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
12.5.2.4
12.5.2.5
12.5.2.6
12.5.2.7
12.5.2.8
12.5.2.9
26
SAM3S16
Memory management fault
Bus fault
Usage fault
SVCall
PendSV
SysTick
A memory management fault is an exception that occurs because of a memory protection
related fault. The MPU or the fixed memory protection constraints determines this fault, for both
instruction and data memory transactions. This fault is used to abort instruction accesses to
Execute Never (XN) memory regions, even if the MPU is disabled.
A bus fault is an exception that occurs because of a memory related fault for an instruction or
data memory transaction. This might be from an error detected on a bus in the memory system.
A usage fault is an exception that occurs because of a fault related to instruction execution. This
includes:
The following can cause a usage fault when the core is configured to report them:
A supervisor call (SVC) is an exception that is triggered by the SVC instruction. In an OS envi-
ronment, applications can use SVC instructions to access OS kernel functions and device
drivers.
PendSV is an interrupt-driven request for system-level service. In an OS environment, use
PendSV for context switching when no other exception is active.
A SysTick exception is an exception the system timer generates when it reaches zero. Software
can also generate a SysTick exception. In an OS environment, the processor can use this
exception as system tick.
• an undefined instruction
• an illegal unaligned access
• invalid state on instruction execution
• an error on exception return.
• an unaligned address on word and halfword memory access
• division by zero.