C8051F502-IMR Silicon Laboratories Inc, C8051F502-IMR Datasheet - Page 66

no-image

C8051F502-IMR

Manufacturer Part Number
C8051F502-IMR
Description
MCU 8-Bit C8051F50x 8051 CISC 64KB Flash 2.5V/3.3V/5V 32-Pin QFN EP T/R
Manufacturer
Silicon Laboratories Inc
Datasheet

Specifications of C8051F502-IMR

Package
32QFN EP
Device Core
8051
Family Name
C8051F50x
Maximum Speed
50 MHz
Ram Size
4.25 KB
Program Memory Size
64 KB
Operating Supply Voltage
2.5|3.3|5 V
Data Bus Width
8 Bit
Program Memory Type
Flash
Number Of Programmable I/os
25
Interface Type
I2C/SPI/UART
On-chip Adc
32-chx12-bit
Operating Temperature
-40 to 125 °C
Number Of Timers
4

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F502-IMR
0
C8051F50x/F51x
SFR Definition 6.8. ADC0TK: ADC0 Tracking Mode Select
SFR Address = 0xBA; SFR Page = 0x00;
6.4. Programmable Window Detector
The ADC Programmable Window Detector continuously compares the ADC0 output registers to user-pro-
grammed limits, and notifies the system when a desired condition is detected. This is especially effective in
an interrupt-driven system, saving code space and CPU bandwidth while delivering faster system
response times. The window detector interrupt flag (AD0WINT in register ADC0CN) can also be used in
polled mode. The ADC0 Greater-Than (ADC0GTH, ADC0GTL) and Less-Than (ADC0LTH, ADC0LTL)
registers hold the comparison values. The window detector flag can be programmed to indicate when mea-
sured data is inside or outside of the user-programmed limits, depending on the contents of the ADC0
Less-Than and ADC0 Greater-Than registers.
66
Name
Reset
7:4
3:2
1:0
Bit
Type
Bit
AD0PWR[3:0] ADC0 Burst Power-Up Time.
AD0TM[1:0]
AD0TK[1:0]
Name
7
1
AD0PWR
For BURSTEN = 0: ADC0 Power state controlled by AD0EN
For BURSTEN = 1, AD0EN = 1: ADC0 remains enabled and does not enter the
very low power state
For BURSTEN = 1, AD0EN = 0: ADC0 enters the very low power state and is
enabled after each convert start signal. The Power-Up time is programmed accord-
ing the following equation:
ADC0 Tracking Mode Enable Select Bits.
00: Reserved.
01: ADC0 is configured to Post-Tracking Mode.
10: ADC0 is configured to Pre-Tracking Mode.
11: ADC0 is configured to Dual Tracking Mode.
ADC0 Post-Track Time.
00: Post-Tracking time is equal to 2 SAR clock cycles + 2 FCLK cycles.
01: Post-Tracking time is equal to 4 SAR clock cycles + 2 FCLK cycles.
10: Post-Tracking time is equal to 8 SAR clock cycles + 2 FCLK cycles.
11: Post-Tracking time is equal to 16 SAR clock cycles + 2 FCLK cycles.
AD0PWR[3:0]
6
1
R/W
=
5
1
Tstartup
----------------------- - 1
200ns
Rev. 1.2
4
1
or
Tstartup
Function
3
1
AD0TM[1:0]
R/W
=
2
1
AD0PWR
1
1
+
AD0TK[1:0]
1
200ns
R/W
0
1

Related parts for C8051F502-IMR