Datasheet

Specifications of MC9S08GT16CFB

Cpu Family
HCS08
Device Core Size
8b
Frequency (max)
20MHz
Interface Type
SCI/SPI
Program Memory Type
Flash
Program Memory Size
16KB
Total Internal Ram Size
1KB
# I/os (max)
36
Number Of Timers - General Purpose
4
Operating Supply Voltage (typ)
2.5/3.3V
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
2.08V
On-chip Adc
8-chx10-bit
Instruction Set Architecture
CISC
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
44
Package Type
PQFP
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC9S08GT16CFB
Manufacturer:
FREESCALE
Quantity:
885
Part Number:
MC9S08GT16CFBE
Manufacturer:
FREESCALE
Quantity:
1 831
Part Number:
MC9S08GT16CFBE
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC9S08GT16CFBE
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MC9S08GT16CFBER
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
ICR — IIC Clock Rate
Freescale Semiconductor
The ICR bits are used to prescale the bus clock for bit rate selection. These bits are used to define the
SCL divider and the SDA hold value. The SCL divider multiplied by the value provided by the MULT
register (multiplier factor mul) is used to generate IIC baud rate.
SDA hold time is the delay from the falling edge of the SCL (IIC clock) to the changing of SDA (IIC
data). The ICR is used to determine the SDA hold value.
Table 13-3
values can be used to set IIC baud rate and SDA hold time. For example:
Table 13-3
in an SDA hold value of 9.
If the generated SDA hold value is not acceptable, the MULT bits can be used to change the ICR. This
will result in a different SDA hold value.
IIC baud rate = bus speed (Hz)/(mul * SCL divider)
SDA hold time = bus period (s) * SDA hold value
Bus speed = 8 MHz
MULT is set to 01 (mul = 2)
Desired IIC baud rate = 100 kbps
IIC baud rate = bus speed (Hz)/(mul * SCL divider)
100000 = 8000000/(2*SCL divider)
SCL divider = 40
SDA hold time = bus period (s) * SDA hold value
SDA hold time = 1/8000000 * 9 = 1.125 µs
provides the SCL divider and SDA hold values for corresponding values of the ICR. These
shows that ICR must be set to 0B to provide an SCL divider of 40 and that this will result
MC9S08GB/GT Data Sheet, Rev. 2.3
Inter-Integrated Circuit (IIC) Module
213