EP2AGX190FF35C6N Altera, EP2AGX190FF35C6N Datasheet - Page 124

no-image

EP2AGX190FF35C6N

Manufacturer Part Number
EP2AGX190FF35C6N
Description
IC ARRIA II GX 190K 1152FBGA
Manufacturer
Altera
Series
Arria II GXr

Specifications of EP2AGX190FF35C6N

Number Of Logic Elements/cells
181165
Number Of Labs/clbs
7612
Total Ram Bits
9939
Number Of I /o
612
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
1152-FBGA
Family Name
Arria® II GX
Number Of Logic Blocks/elements
190300
# I/os (max)
612
Frequency (max)
400MHz
Operating Supply Voltage (typ)
900mV
Logic Cells
190300
Ram Bits
10380902.4
Operating Supply Voltage (min)
0.87V
Operating Supply Voltage (max)
0.93V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
1152
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2AGX190FF35C6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2AGX190FF35C6N
Manufacturer:
ALTERA
0
Part Number:
EP2AGX190FF35C6N
0
5–32
Figure 5–25. PLL Reconfiguration Waveform
Arria II GX Device Handbook, Volume 1
CONFIGUPDATE
SCANDATAOUT
SCANCLKENA
SCANDONE
SCANDATA
SCANCLK
ARESET
1
Dn_old
To reconfigure the PLL counters, follow these steps:
1. Assert the scanclkena signal at least one scanclk cycle prior to shifting in the
2. Serial data (scandata) is shifted into the scan chain on the second rising edge of
3. After all 180 bits are scanned into the scan chain, the scanclkena signal is
4. The configupdate signal is asserted for one scanclk cycle to update the PLL
5. The scandone signal goes high indicating the PLL is being reconfigured. A falling
6. Reset the PLL with the areset signal if you make any changes to the M, N, or
7. Repeat steps
Figure 5–25
When you reconfigure the counter clock frequency, you cannot reconfigure the
corresponding counter phase shift settings with the same interface. Instead,
reconfigure the phase shifts in real time with the dynamic phase shift reconfiguration
interface. If you reconfigure the counter frequency, but want to keep the same
non-zero phase shift setting (for example, 90°) on the clock output, you must
reconfigure the phase shift immediately after reconfiguring the counter clock
frequency.
Post-Scale Counters (C0 to C6)
You can configure the multiply or divide values and duty cycle of post-scale counters
in real time. Each counter has an 8-bit high-time setting and an 8-bit low-time setting.
The duty cycle is the ratio of output high- or low-time to the total cycle time, which is
the sum of the two. Additionally, these counters have two control bits, rbypass, for
bypassing the counter, and rselodd, to select the output clock duty cycle.
first bit of scandata (Dn).
scanclk.
deasserted to prevent inadvertent shifting of bits in the scan chain.
counters with the contents of the scan chain.
edge indicates the PLL counters are updated with new settings.
post-scale output C counters or the Icp, R, or C settings.
Dn
shows a functional simulation of the PLL reconfiguration feature.
1
through
5
to reconfigure the PLL any number of times.
Chapter 5: Clock Networks and PLLs in Arria II GX Devices
D0_old
D0
Dn
© July 2010 Altera Corporation
PLLs in Arria II GX Devices

Related parts for EP2AGX190FF35C6N