Specifications of S1D13700F01A100

Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Temperature Classification
Industrial
Package Type
TQFP
Pin Count
80
Mounting
Surface Mount
Operating Supply Voltage (min)
2.7V
Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S1D13700F01A100
Manufacturer:
MTK
Quantity:
5 000
Part Number:
S1D13700F01A100
Manufacturer:
Epson Electronics America Inc-Semiconductor Div
Quantity:
10 000
Part Number:
S1D13700F01A100
Manufacturer:
EPSON/爱普生
Quantity:
20 000
Generic #1 Interface Mode
S1D13705F00A APPLICATION NOTES
(X27A-G-007-01)
Generic #1 interface mode is the most general and least processor-specific interface mode on the
S1D13705. The Generic # 1 interface mode was chosen for this interface due to the simplicity of its
timing.
The interface requires the following signals:
• BUSCLK is a clock input which is required by the S1D13705 host interface. It is separate from
• The address inputs AB0 through AB16, and the data bus DB0 through DB15, connect directly to
• Chip Select (CS#) is driven by decoding the high-order address lines to select the proper register
• WE0# and WE1# are write enables for the low-order and high-order bytes, respectively, to be
• RD# and RD/WR# are read enables for the low-order and high-order bytes, respectively, to be
• WAIT# is a signal output from the S1D13705 that indicates the host CPU must wait until data is
• The Bus Status (BS#) signal is not used in the bus interface for Generic #1 mode. However, BS# is
the input clock (CLKI) and is typically driven by the host CPU system clock.
the CPU address and data bus, respectively. On 32-bit big endian architectures such as the Power
PC, the data bus would connect to the high-order data lines; on little endian hosts, or 16-bit big
endian hosts, they would connect to the low-order data lines. The hardware engineer must ensure
that CNF3 selects the proper endian mode upon reset.
and memory address space.
driven low when the host CPU is writing data to the S1D13705. These signals must be generated
by external hardware based on the control outputs from the host CPU.
driven low when the host CPU is reading data from the S1D13705. These signals must be gener-
ated by external hardware based on the control outputs from the host CPU.
ready (read cycle) or accepted (write cycle) on the host bus. Since host CPU accesses to the
S1D13705 may occur asynchronously to the display update, it is possible that contention may
occur in accessing the S1D13705 internal registers and/or refresh memory. The WAIT# line
resolves these contentions by forcing the host to wait until the resource arbitration is complete.
This signal is active low and may need to be inverted if the host CPU wait state signal is active
high.
used to configure the S1D13705 for Generic #1 mode and should be tied low (connected to GND).
1: INTERFACING TO THE MOTOROLA MC68328 “DRAGONBALL” MICROPROCESSOR
EPSON
5-3

Related parts for S1D13700F01A100