2-9-3 B7A Interface Unit Part Names
2-9-4 Installing the B7A Interface Unit
66
Connection of Expanded I/O
Connector (on rear face)
This is the connector for connecting
the Unit to the NT30/30C.
Mounting screws (see below)
These secure the Unit to the
NT30/30C.
Reference
Caution
*1
*2
*3
The function of each part of the B7A Interface Unit is indicated below.
(1) Peel off the label on the right side of the rear face of the NT30/30C. Under-
Be sure to switch OFF the power supply to both the NT30/30C and the B7A Inter-
face Unit before installing the B7A Interface Unit, otherwise the Units may be
damaged.
When the B7A Interface Unit is installed, the depth of the NT30/30C is increased
by 20 mm to 76 mm. Before installing the B7A Unit, check that there is sufficient
space inside the operation panel to accommodate this extra depth.
Dielectric strength
Noise resistance (*3)
Vibration resistance
Shock resistance
Operating ambient temperature
Operating ambient humidity
Storage ambient temperature
Weight
This is the value when a shielded cable is used. If no shielded cable is used,
the maximum transmission distance will be 10 m, regardless of the method
used to supply power.
The least input time is the least time required for the B7A Interface Unit to
read an input signal.
This is induced noise due to coupling with the transmission line. For
high-speed transmission, this is the value when the shield is not grounded.
neath the label are the connector and screw holes for installing the B7A In-
terface Unit.
Model
1,000 VAC, 50/60 Hz, 1min. between all terminals
together and external reference
Noise level: 1.5 kV, Pulse width: 100 ns, 1 μs
10 to 22 Hz with 0.075 mm single amplitude for a total of
30 min. in X, Y, and Z directions
22 to 500 Hz with 4.7 m/s
directions
490 m/s
times each in X, Y, and Z directions
0 to 50_C
35 to 85%RH (with no condensation)
100 g max.
--20 to 70_C
Indicator (LED)
While the NT30/30C power is ON, this indicator
gives the following indications.
DIP switch (SW1) (see page 66)
Used to set the operating conditions
of the B7A Interface Unit.
Terminal block (see page 68)
For connecting the power supply for transmission
and the B7A Interface Unit.
Lit in green:
Lit in red:
2
(not operating) or 29.4 m/s
NT30/30C is operating
A transmission error has occurred.
NT-B7A16
2
acceleration in X, Y, and Z
Section
2
(operating), 3
2-9