NT30-KBA04 Omron, NT30-KBA04 Datasheet - Page 246

no-image

NT30-KBA04

Manufacturer Part Number
NT30-KBA04
Description
ANTI GLARE COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA04

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
5-6-3 Date and Time Setting
Clock Function
DM
CH
TIM
CNT
HR
AR
LR
Sym-
bol
Procedure 1. Allocate the two memory table entries that are to be the copy source for the
Reference
DM Area
IR Area
Timer Area
Counter Area
HR Area
AR Area
LR Area
C Series PC
95 / 03 / 21
9 / 50 / 18
NT30/30C
When the date and time are set from the PC, the contents of the numeral memory
table entries numbered 254 and 255 are rewritten. It is possible to use the meth-
od of copying between memory table entries to set the time, as shown below.
Numeral memory table entries 254 and 255 are exclusively for time setting. They
can be allocated to an area of the PC for other uses. It is possible to rewrite the
contents of these memory table entries by first writing the new setting into table
entries other than 254 and 255 and then copying it into table entries 254 and 255
by using the memory table entry copy function.
S Available allocation words
The Auxiliary Area of CV series PC is used exclusively for special applications in
the system, and cannot be used for other application.
S t is also possible to set the date and time by using function key [F3] (Time) on
S It is also possible to set the date and time by rewriting the contents of numeral
The memory table can be allocated words in the following PC areas. For time
setting, two words have to be allocated for each table entry.
The range of respective area varies with the type of PC. Refer to the appendix
PC Memory Maps (page 291).
the Tool Settings screen of the NT-series Support Tool.
For details, see the NT-series Support Tool for Windows Operation Manual
(V061).
memory table entries 254 and 255 using the numeral setting function.
setting to areas in the PC. Two words must be allocated for each table entry.
Alloca-
tion
f
f
×
×
f
f
f
254
255
0
1
DM Area
CIO Area
Timer
Counter Area
Auxiliary Area
CVM1/CV Series PC
Date, hour,
minute, second
Day of wheek,
year, month
Date, hour,
minute, second
Day of wheek,
year, month
--
--
DM0000
DM0002
--
--
Alloca-
tion
×
×
×
f
f
--
--
Copy
DM Area
CIO Area
Timer
Counter Area
HR Area
Auxiliary Area
CS1 Series PC
--
Minute, second
Section
Day of week
Year, month
Date, hour
PC
f
×
: Possible
: Impossible
Alloca-
DM0000
DM0001
DM0002
DM0003
tion
×
×
×
×
f
f
--
235
5-6