NT30-KBA04 Omron, NT30-KBA04 Datasheet - Page 103

no-image

NT30-KBA04

Manufacturer Part Number
NT30-KBA04
Description
ANTI GLARE COVER FOR NT31
Manufacturer
Omron
Datasheets

Specifications of NT30-KBA04

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Confirming the Communications between the NT30/30C and the PC
3-8
3-8-1 Setting the Key Press Sound
92
System Settings
System Settings
Reference
Execute the PC program and confirm that the following operations are normally
performed.
The NT30/30C can set a variety of functions using memory switches that are
convenient during the operation. This section describes the memory switch set-
tings related to the operation environment.
The memory switches can also be set in “System Setting” under “PT Configura-
tion” on the NT-series Support Tool. The settings made using the NT-series Sup-
port Tool are written to the NT30/30C on screen data registration. For details,
refer to the NT-series Support Tool for Windows Operation Manual (V061).
Since the memory switch data are backed up by the battery in the NT30/30C,
they are not cleared when the power is switched OFF.
It is possible to set whether or not the key sound is sounded when a touch switch
on the NT30/30C screen is pressed or an expanded I/O input comes ON by using
the Key Press Sound memory switch.
The factory setting for this memory switch is ON, which means that the key sound
will sound in these cases.
Set the key press sound by the menu operation from the System Menu shown
below.
If the memory switch data is not backed up by the built-in battery, it will all be
initialized to the values set with the NT-series Support Tool when the NT30/30C
is switched OFF. If the message “Battery Lowered” is displayed while the
NT30/30C is operating, replace the built-in battery immediately. For details on
how to replace the battery, see Replacing the Battery (page 253).
• Confirm that the NT30/30C screens switch according to the PC program
• Confirm that the information selected by the NT30/30C touch switches has
[ SYSTEM MENU ]
If the screens do not switch correctly, check the connection between the
NT30/30C and the PC and also check the settings.
Refer to Section 2 Hardware Settings and Connections (page 15).
For the details of the screen data creation, refer to the NT-series Support Tool
Operation Manual.
Maintenance Mode
execution.
been set in the PC by displaying the contents of the words and bits using a Pro-
gramming Device (LSS) or at the Host. If the information sent from the
NT30/30C has not been correctly received by the PC, check the screen data
settings (specifically the switch settings).
Transmit Mode
Quit
Select “Maintenance Mode.”
Section
3-8

Related parts for NT30-KBA04