ATA5771-DK1 Atmel, ATA5771-DK1 Datasheet - Page 122

no-image

ATA5771-DK1

Manufacturer Part Number
ATA5771-DK1
Description
BOARD XMITTER FOR ATA5771 868MHZ
Manufacturer
Atmel
Type
Transmitterr
Datasheets

Specifications of ATA5771-DK1

Frequency
868MHz
Maximum Frequency
868 MHz
Supply Voltage (max)
4 V
Supply Voltage (min)
2 V
Supply Current
8.5 mA
Product
RF Development Tools
For Use With/related Products
ATA5771
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4.16.11.9
122
Atmel ATA5771/73/74
TIFR1 – Timer/Counter Interrupt Flag Register 1
• Bit 7,6,4,3 – Reserved Bit
This bit is reserved for future use. For ensuring compatibility with future devices, this bit must
be written to zero when the register is written.
• Bit 5– ICF1: Timer/Counter1, Input Capture Flag
This flag is set when a capture event occurs on the ICP1 pin. When the Input Capture Register
(ICR1) is set by the WGM13:0 to be used as the TOP value, the ICF1 flag is set when the
counter reaches the TOP value.
ICF1 is automatically cleared when the Input Capture Interrupt Vector is executed. Alterna-
tively, ICF1 can be cleared by writing a logic one to its bit location.
• Bit 2– OCF1B: Timer/Counter1, Output Compare B Match Flag
This flag is set in the timer clock cycle after the counter (TCNT1) value matches the Output
Compare Register B (OCR1B).
Note that a Forced Output Compare (1B) strobe will not set the OCF1B flag.
OCF1B is automatically cleared when the Output Compare Match B Interrupt Vector is exe-
cuted. Alternatively, OCF1B can be cleared by writing a logic one to its bit location.
• Bit 1– OCF1A: Timer/Counter1, Output Compare A Match Flag
This flag is set in the timer clock cycle after the counter (TCNT1) value matches the Output
Compare Register A (OCR1A).
Note that a Forced Output Compare (1A) strobe will not set the OCF1A flag.
OCF1A is automatically cleared when the Output Compare Match A Interrupt Vector is exe-
cuted. Alternatively, OCF1A can be cleared by writing a logic one to its bit location.
• Bit 0– TOV1: Timer/Counter1, Overflow Flag
The setting of this flag is dependent of the WGM13:0 bits setting. In Normal and CTC modes,
the TOV1 flag is set when the timer overflows. See
behavior when using another WGM13:0 bit setting.
TOV1 is automatically cleared when the Timer/Counter1 Overflow Interrupt Vector is exe-
cuted. Alternatively, TOV1 can be cleared by writing a logic one to its bit location.
Bit
0x0B (0x2B)
Read/Write
Initial Value
R
7
0
R
6
0
ICIF1
R/W
5
0
R
4
0
Table 4-42 on page 118
R
3
0
OCF1B
R/W
2
0
OCF1A
R/W
1
0
TOV1
for the TOV1 flag
R/W
0
0
9137E–RKE–12/10
TIFR1

Related parts for ATA5771-DK1