C8051F321-GM Silicon Laboratories Inc, C8051F321-GM Datasheet - Page 181

IC 8051 MCU 16K FLASH 28MLP

C8051F321-GM

Manufacturer Part Number
C8051F321-GM
Description
IC 8051 MCU 16K FLASH 28MLP
Manufacturer
Silicon Laboratories Inc
Series
C8051F32xr
Datasheets

Specifications of C8051F321-GM

Program Memory Type
FLASH
Program Memory Size
16KB (16K x 8)
Package / Case
28-VQFN Exposed Pad, 28-HVQFN, 28-SQFN, 28-DHVQFN
Core Processor
8051
Core Size
8-Bit
Speed
25MHz
Connectivity
SMBus (2-Wire/I²C), SPI, UART/USART, USB
Peripherals
Brown-out Detect/Reset, POR, PWM, Temp Sensor, WDT
Number Of I /o
21
Ram Size
2.25K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 13x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Processor Series
C8051F3x
Core
8051
Data Bus Width
8 bit
Data Ram Size
2.25 KB
Interface Type
I2C/SMBus/SPI/UART/USB
Maximum Clock Frequency
25 MHz
Number Of Programmable I/os
21
Number Of Timers
4
Operating Supply Voltage
2.7 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Development Tools By Supplier
C8051F320DK
Minimum Operating Temperature
- 40 C
On-chip Adc
13-ch x 10-bit or 17-ch x 10-bit
No. Of I/o's
21
Ram Memory Size
1280Byte
Cpu Speed
25MHz
No. Of Timers
4
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
336-1480 - DAUGHTER CARD TOOLSTCK C8051F321770-1006 - ISP 4PORT FOR SILABS C8051F MCU336-1449 - ADAPTER PROGRAM TOOLSTICK F321336-1260 - DEV KIT FOR C8051F320/F321
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1261

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F321-GM
Manufacturer:
SiliconL
Quantity:
4 364
Part Number:
C8051F321-GM
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Part Number:
C8051F321-GMR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Company:
Part Number:
C8051F321-GMR
Quantity:
60 000
Figure 16.4 shows the typical SCL generation described by Equation 16.2. Notice that T
large as T
slave devices, or driven low by contending master devices). The bit rate when operating as a master will never exceed
the limits defined by equation Equation 16.1.
Setting the EXTHOLD bit extends the minimum setup and hold times for the SDA line. The minimum SDA setup
time defines the absolute minimum time that SDA is stable before SCL transitions from low-to-high. The minimum
SDA hold time defines the absolute minimum time that the current SDA value remains stable after SCL transitions
from high-to-low. EXTHOLD should be set so that the minimum setup and hold times meet the SMBus Specification
requirements of 250 ns and 300 ns, respectively. Table 16.2 shows the minimum setup and hold times for the two
EXTHOLD settings. Setup and hold time extensions are typically necessary when SYSCLK is above 10 MHz.
With the SMBTOE bit set, Timer 3 should be configured to overflow after 25 ms in order to detect SCL low timeouts
(see
SCL is high, and allow Timer 3 to count when SCL is low. The Timer 3 interrupt service routine should be used to
reset SMBus communication by disabling and re-enabling the SMBus.
SMBus Free Timeout detection can be enabled by setting the SMBFTE bit. When this bit is set, the bus will be con-
sidered free if SDA and SCL remain high for more than 10 SMBus clock source periods (see Figure 16.4). When a
Free Timeout is detected, the interface will respond as if a STOP was detected (an interrupt will be generated, and
STO will be set).
Timer Source
Section “16.3.3. SCL Low Timeout” on page
Overflows
LOW
SCL
EXTHOLD
occurs between the time SMB0DAT or ACK is written and when SI is cleared. Note that if
SI is cleared in the same write that defines the outgoing ACK value, s/w delay is zero.
. The actual SCL output may vary due to other devices on the bus (SCL may be extended low by slower
Setup Time for ACK bit transmissions and the MSB of all data transfers. The s/w delay
0
1
T
Low
Table 16.2. Minimum SDA Setup and Hold Times
Figure 16.4. Typical SMBus SCL Generation
Minimum SDA Setup Time
1 system clock + s/w delay
T
low
11 system clocks
- 4 system clocks
T
High
OR
178). The SMBus interface will force Timer 3 to reload while
Rev. 1.1
Minimum SDA Hold Time
SCL High Timeout
12 system clocks
3 system clocks
C8051F320/1
HIGH
is typically twice as
181