Z8F2480AN020SG Zilog, Z8F2480AN020SG Datasheet - Page 134

MCU 8BIT 24KB FLASH 44LQFP

Z8F2480AN020SG

Manufacturer Part Number
Z8F2480AN020SG
Description
MCU 8BIT 24KB FLASH 44LQFP
Manufacturer
Zilog
Series
Encore!® XP®r
Datasheets

Specifications of Z8F2480AN020SG

Core Processor
Z8
Core Size
8-Bit
Speed
20MHz
Connectivity
I²C, IrDA, LIN, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, LED, LVD, POR, PWM, Temp Sensor, WDT
Number Of I /o
37
Program Memory Size
24KB (24K x 8)
Program Memory Type
FLASH
Ram Size
3K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
0°C ~ 70°C
Package / Case
44-LQFP
Processor Series
Z8F248x
Core
eZ8
Data Bus Width
8 bit
Data Ram Size
2 KB
Interface Type
I2C, SPI, UART
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
37
Number Of Timers
3
Maximum Operating Temperature
+ 70 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
0 C
On-chip Adc
10 bit, 8 Channel
For Use With
770-1002 - ISP 4PORT ZILOG Z8 ENCORE! MCU269-4643 - KIT DEV Z8 ENCORE XP 28-PIN269-4630 - DEV KIT FOR Z8 ENCORE 8K/4K269-4629 - KIT DEV Z8 ENCORE XP 28-PIN269-4628 - KIT DEV Z8 ENCORE XP 8-PIN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
269-4676

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
Z8F2480AN020SG
Manufacturer:
Zilog
Quantity:
85
Part Number:
Z8F2480AN020SG
Manufacturer:
Zilog
Quantity:
10 000
Timer Operation
PS025011-1010
Multi-Channel Timer Counter
Clock Source
Multi-Channel Timer Clock Prescaler
Multi-Channel Timer Start
Multi-Channel Timer Mode Control
The Multi-Channel Timer is based around a 16-bit up/down counter. The counter,
depending on the TIMER mode counts up or down with each rising edge of 
the clock signal. Timer Counter Registers MCTH and MCTL can be read/written 
by software.
The Multi-Channel Timer clock source can come from either the system clock or 
the system clock gated by the alternate function TIN pin, the alternate function 
TIN input pin operating as a clock input of gated clock. The TCLKS field in the
MCTCTL0 register selects the timer clock source. When using the TIN pin, the associated
GPIO pin must be configured as an input. The TIN frequency cannot exceed one-fourth
the system clock frequency.
The prescaler allows the system clock signal to be decreased by factors of 1, 2, 4, 8, 16,
32, 64, or 128. The PRES[2:0] bit field in the MCTCTL1 register controls prescaler
operation. The PRES field is buffered for the prescale value to change only on a 
MCT end of cycle count. The prescaler has no effect when the TIN is selected as 
the clock source.
The Multi-Channel Timer starts counting when TEN bit in MCTCTL1 register is set and
the clock source is active. In Count Modulo or Count up/down mode the timer counting
can be stopped without disabling the timer by setting the Reload Register to 0. The timer
will then stop when the counter next reaches 0. Writing a nonzero value to the Reload
Register restarts the timer counting.
The Multi-Channel Timer supports two modes of operation: Count Modulo and Count 
up/down. The operating mode is selected with the TMODE[1:0] field in MCTCTL1
register. The timer modes are described below in
P R E L I M I N A R Y
Table 65
Z8 Encore! XP
on page 121.
Product Specification
Multi-Channel Timer
®
F1680 Series
120

Related parts for Z8F2480AN020SG