T89C51CC01CA-7CTIM Atmel, T89C51CC01CA-7CTIM Datasheet - Page 147

IC 8051 MCU FLASH 32K 64BGA

T89C51CC01CA-7CTIM

Manufacturer Part Number
T89C51CC01CA-7CTIM
Description
IC 8051 MCU FLASH 32K 64BGA
Manufacturer
Atmel
Series
AT89C CANr

Specifications of T89C51CC01CA-7CTIM

Core Processor
8051
Core Size
8-Bit
Speed
40MHz
Connectivity
CAN, UART/USART
Peripherals
POR, PWM, WDT
Number Of I /o
34
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Eeprom Size
2K x 8
Ram Size
1.25K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
64-BGA
For Use With
AT89STK-06 - KIT DEMOBOARD 8051 MCU W/CAN
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
T89C51CC01CA7CTIM

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
T89C51CC01CA-7CTIM
Manufacturer:
Atmel
Quantity:
10 000
DC Parameters for A/D Converter
Table 122. DC Parameters for AD Converter in Precision Conversion
AC Parameters
Explanation of the AC
Symbols
4129N–CAN–03/08
Symbol
Rref
Varef
AVin
DNL
Cai
Rai
INL
OE
(2)
Parameter
Analog input voltage
Resistance between Vref and Vss
Reference voltage
Analog input Capacitance
Analog input Resistor
Integral non linearity
Differential non linearity
Offset error
Notes:
Each timing symbol has 5 characters. The first character is always a “T” (stands for
time). The other characters, depending on their positions, stand for the name of a signal
or the logical status of that signal. The following is a list of all the characters and what
they stand for.
Example: T
T
T
(Load Capacitance for port 0, ALE and PSEN = 60 pF; Load Capacitance for all other
outputs = 60 pF.)
Table 123, Table 126 and Table 129 give the description of each AC symbols.
Table 124, Table 128 and Table 130 give for each range the AC parameter.
Table 125, Table 128 and Table 131 give the frequency derating formula of the AC
parameter for each speed range description. To calculate each AC symbols: Take the x
value and use this value in the formula.
Example: T
x = 30 ns
T = 50 ns
T
A
A
CCIV
T
= -40°C to +85°C; V
= -40°C to +85°C; V
LLPL
= 4T - x = 170 ns
= Time for ALE Low to PSEN Low.
1. Typicals are based on a limited number of samples and are not guaranteed.
2. With ADC enabled.
AVLL
LLIV
and 20 MHz, Standard clock.
= Time for Address Valid to ALE Low.
Vss- 0.2
SS
SS
Min
2.40
12
-2
= 0V; V
= 0V; V
CC
CC
Typ
= 5V ±10%; F = 0 to 40 MHz.
= 5V ± 10%.
0.5
16
60
1
(1)
Vref
Max
3.00
400
24
2
1
2
+ 0.2
Unit
kΩ
lsb
lsb
lsb
pF
V
V
Test Conditions
During sampling
During sampling
147