C8051F930DK Silicon Laboratories Inc, C8051F930DK Datasheet - Page 197

KIT DEV C8051F920,F921,F930,F931

C8051F930DK

Manufacturer Part Number
C8051F930DK
Description
KIT DEV C8051F920,F921,F930,F931
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheets

Specifications of C8051F930DK

Contents
Target Board, Power Adapter, USB Debug Adapter, Cables, Batteries, and Software
Processor To Be Evaluated
C8051F930
Processor Series
C8051F9xx
Data Bus Width
8 bit
Interface Type
I2C, UART, SPI
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Operating Supply Voltage
0.9 V to 3.6 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
C8051F920, F921, F930, F931
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1473

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F930DK
Manufacturer:
Silicon Labs
Quantity:
135
20.1. SmaRTClock Interface
The SmaRTClock Interface consists of three registers: RTC0KEY, RTC0ADR, and RTC0DAT. These inter-
face registers are located on the CIP-51’s SFR map and provide access to the SmaRTClock internal regis-
ters listed in Table 20.1. The SmaRTClock internal registers can only be accessed indirectly through the
SmaRTClock Interface.
Table 20.1. SmaRTClock Internal Registers
20.1.1. SmaRTClock Lock and Key Functions
The SmaRTClock Interface is protected with a lock and key function. The SmaRTClock Lock and Key Reg-
ister (RTC0KEY) must be written with the correct key codes, in sequence, before writes and reads to
RTC0ADR and RTC0DAT may be performed. The key codes are: 0xA5, 0xF1. There are no timing restric-
tions, but the key codes must be written in order. If the key codes are written out of order, the wrong codes
are written, or an indirect register read or write is attempted while the interface is locked, the SmaRTClock
interface will be disabled, and the RTC0ADR and RTC0DAT registers will become inaccessible until the
next system reset. Once the SmaRTClock interface is unlocked, software may perform any number of
accesses to the SmaRTClock registers until the interface is re-locked or the device is reset. Any write to
RTC0KEY while the SmaRTClock interface is unlocked will re-lock the interface.
Reading the RTC0KEY register at any time will provide the SmaRTClock Interface status and will not inter-
fere with the sequence that is being written. The RTC0KEY register description in SFR Definition 20.1 lists
the definition of each status code.
SmaRTClock
0x08–0x0B
0x00–0x03
Address
0x04
0x05
0x06
0x07
SmaRTClock
CAPTUREn SmaRTClock Capture
RTC0XCN
RTC0XCF
RTC0PIN
Register
RTC0CN
ALARMn
Registers
SmaRTClock Control
Register
SmaRTClock Oscillator
Control Register
SmaRTClock Oscillator
Configuration Register
SmaRTClock Pin
Configuration Register
SmaRTClock Alarm
Registers
Register Name
Rev. 1.1
C8051F93x-C8051F92x
Four Registers used for setting the 32-bit
SmaRTClock timer or reading its current value.
Controls the operation of the SmaRTClock State
Machine.
Controls the operation of the SmaRTClock
Oscillator.
Controls the value of the programmable
oscillator load capacitance and
enables/disables AutoStep.
Forces XTAL3 and XTAL4 to be internally
shorted.
Note: This register also contains other reserved bits
Four registers used for setting or reading the
32-bit SmaRTClock alarm value.
which should not be modified.